Rigol RSA3045 – 4.5 GHz Real-Time Spectrum Analyzer
$3,509.00
In Stock
In Stock
Rigol RSA3045 - 4.5 GHz Real-Time Spectrum Analyzer Specs
| RSA3030 | RSA3030-TG |
| Frequency Range | 9 kHz to 3.0 GHz |
| Reference Frequency | 10 MHz |
| Accuracy | ±[(time since last calibration × aging rate) + temperature stability + calibration accuracy] |
| Initial Calibration Accuracy | Standard |
| Option OCXO-C08 | <0.1 ppm |
| Temperature Stability | 0℃ to 50℃ , with the reference 25℃ |
| Standard | <0.5 ppm |
| Option OCXO-C08 | <0.005 ppm |
| Aging Rate | Standard |
| Option OCXO-C08 | <0.03 ppm/year |
| Type | capacitive multi-touch screen |
| Resolution | 1024 × 600 pixels |
| Size | 10.1" |
| Color | 24-bit color |
| Protocol | network printer |
| Mass Memory | Internal Storage |
| External Storage | USB storage device (not supplied) |
| Input Voltage Range, AC | 100 V to 240 V (nominal) |
| AC Frequency | 45 Hz to 440 Hz |
| Power Consumption | 55 W (typical), max. 90 W with all options |
| Temperature | Operating Temperature Range |
| Storage Temperature Range | -20℃ to 70℃ |
| Humidity | 0℃ to 30℃ |
| 30℃ to 40℃ | ≤75% RH |
| Altitude | Operating Height |
| EMC | complies with EMC Directive 2014/30/EU, complies with or above the standard specified in IEC61326-1:2013/EN61326-1:2013 Group 1 Class A |
| IEC 61000-4-2:2008/EN 61000-4-2 | ±4.0 kV (contact discharge), ±8.0 kV (air discharge) |
| IEC 61000-4-3:2002/EN 61000-4-3 | 3V/m (80 MHz to 1 GHz); 3V/m (1.4 GHz to 2 GHz); 1V/m (2.0 GHz to 2.7 GHz) |
| IEC 61000-4-4:2004/EN 61000-4-4 | 1 kV power |
| IEC 61000-4-5:2001/EN 61000-4-5 | 0.5 kV (phase-to-neutral voltage); 1 kV (phase-to-earth voltage); 1 kV (neutral-to-earth voltage) |
| IEC 61000-4-6:2003/EN 61000-4-6 | 3 V, 0.15 to 80 MHz |
| IEC 61000-4-11:2004/EN 61000-4-11 | voltage dip: 0% UT during half cycle; 0% UT during 1 cycle; 70% UT during 25 cycles short interruption: 0% UT during 250 cycles |
| Safety | complies with IEC 61010-1:2010 (Third Edition)/EN 61010-1:2010, UL 61010-1:2012 R4.16 and CAN/CSA-C22.2 No. 61010-1-12+ GI1+ GI2 |
| Environmental Stress | Samples of this product have been type tested in accordance with RIGOL's reliability test regulations and verified to be robust against the environmental stresses of storage, transportation, andend-use; those stresses include, but are not limited to, temperature, humidity, shock, and vibration. The test methods are compliant with standards specified in GB/T6587 Class 2 and MILPRF-28800F Class 3. |
| (W x H x D) | 410 mm × 224 mm × 135 mm (16.14'' × 8.82'' × 5.32'') |
| Without Tracking Generator | Without Tracking Generator |
| With Tracking Generator | 4.95 kg (10.91 lb) |
| Recommended Calibration Interval | 18 months |
- Power cord
- User manual
- NIST calibration certificate for the RSA3045











Reviews