Siglent SVA1032X-OB Spectrum Analyzers – Bandwidth Range Max: 3.2 GHz, Bandwidth Range Min: 9 kHz, Noise Floor: -161 dB
$1,988.00
In Stock
In Stock
Siglent SVA1032X-OB Spectrum Analyzers - Bandwidth Range Max: 3.2 GHz, Bandwidth Range Min: 9 kHz, Noise Floor: -161 dB Specs
| Frequency range | 9 kHz ~ 3.2 GHz |
| Frequency resolution | 1 Hz |
| Range | 0 Hz, 100 Hz to Max Frequency |
| Accuracy | ± Span / (number of display points - 1) |
| Reference frequency | 10.000000 MHz |
| Reference frequency accuracy / uncertainty | ± [(time since last adjustment × frequency aging rate) + temperature stability + initial calibration accuracy] |
| Initial calibration accuracy | <1 ppm |
| Temperature stability | <1 ppm/year, 0 °C ~50 °C |
| Frequency aging rate | <0.5 ppm/first year, 3.0 ppm/20 years |
| Marker resolution | Span / (number of display points - 1) |
| Marker uncertainty | ± [frequency indication × reference frequency uncertainty + 1% × span + 10% × resolution bandwidth + marker resolution] |
| Frequency Counter resolution | 0.01 Hz |
| Resolution bandwidth (-3dB) | 1 Hz ~ 1 MHz, in 1-3-10 sequence |
| Resolution filter shape factor | < 4.8 : 1 (60 dB:3 dB), Gaussian-like |
| RBW uncertainty | <5% |
| Video bandwidth (-3dB) | 1 Hz ~ 3 MHz, in 1-3-10 sequence |
| VBW uncertainty | <5% |
| Sweep time | 1 ms to 3200 s |
| RBW | Sweep | 30 Hz ~ 1 MHz FFT | 1 Hz ~ 10 kHz |
| Sweep rule | Single, Continuous |
| Trigger source | Free, Video, External |
| External trigger | 5V TTL level, Rising edge/Falling edge |
| Measurement Range | DANL to +10 dBm, 100 kHz ~ 1 MHz, Preamp off DANL to +20 dBm, 1 MHz ~ 7.5 GHz, Preamp off |
| Reference level | -200 dBm to +30 dBm, 1 dB steps |
| Preamplifier | 20 dB (nom.) |
| Input attenuation | 0 ~ 50 dB, 1 dB steps |
| Maximum input DC voltage | +/- 50 VDC |
| Maximum average power | 30 dBm, 3 minutes, fc ≥10 MHz, att > 20 dBm, preamp off |
| Maximum damage level | 33 dBm, fc ≥ 10 MHz, att > 20 dBm, preamp off |
| Logarithmic level axis | 1 dB to 200 dB |
| Linear level axis | 0 to reference level |
| Units of level axis | dBm, dBmV, dBμV, dBμA, Volt, Watt |
| Number of display points | 751 |
| Number of traces | 4 |
| Trace detectors | Positive-peak, Negative-peak, Sample, Normal, Average(Voltage/RMS/Video), Quasi-peak |
| Trace functions | Clear write, Max Hold, Min Hold, View, Blank, Average, Math |
| Offset | 20 °C to 30 °C, fc = 1 GHz, Normalized to 1 Hz |
| 10 kHz | -95 dBc/Hz, -98 dBc/Hz (typ.) |
| 100 kHz | -96 dBc/Hz, -97 dBc/Hz (typ.) |
| 1 MHz | -115 dBc/Hz, -117 dBc/Hz (typ.) |
| Frequency Range | 100 kHz ~ 3.2 GHz |
| Measurement | S11, S21 |
| IFBW | 10 kHz |
| Port1 Stimulus Power | -5 dBm (nom.) |
| Format | Lin Mag, Log Mag, Phase, Group Delay, SWR, Smith Chart (Lin/Phase, Log/Phase, Real/Imag, R+j*X, G+j*B), Polar Chart (Lin/Phase, Log/Phase, Real/Imag) |
| Sweep Points | 101~751, default 201 |
| Trace | 4 traces, Mem, Math, Hold, Overlay |
| Marker | (6+Ref)* 4 traces |
- Quick start guide
- USB cable
- Power cord
- NMI traceable calibration certificate (NIST equivalent)











Reviews