Fluke Networks DSX2-8000QOI/GLD 2 GHz DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection, Wi-Fi and 1 Year of Gold Support
$31,259.00
In Stock
Fluke Networks DSX2-8000QOI/GLD combining integrated Wi-Fi wireless capabilities stabilizes high-volume commercial data infrastructure certifications across enterprise cloud architectures while backed by 1 year of comprehensive Gold Support.
- 2 GHz maximum testing frequency benchmarks links.
- 800 m copper distance range traces paths.
- 540 Ω total loop resistance tracks loops.
- 10 ns delay skew accuracy detects imbalances.
- 1 m drop impact protection secures units.
In Stock
Fluke Networks DSX2-8000QOI/GLD 2 GHz DSX2-8000 Cable Analyzer with Quad OTDR, Quad OLTS, Fiber Inspection, Wi-Fi and 1 Year of Gold Support Specs
| Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |
| Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI |
| Without Remote | With Remote |
| Range | 800 m (2600 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
| Without Remote | With Remote |
| Range | 4000 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
| Range | 0 ns to 100 ns |
| Resolution | 1 ns |
| Accuracy | ± 10 ns |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
| Input Connector | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
| Detector Type | InGaAs |
| Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
| Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
| Power Measurement Uncertainty1,2 | < +/- 5% +/- 32 pW |
| Measurement Linearity3 | < ± 0.1 dB |
| Re-calibration Period | 1 year |
| Specification | CertiFiber Pro Multimode Modules |
| Testing Speeds (excludes referencing times) | Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
| Input/Output Connectors | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
| Launch Condition1,2 | Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
| Fiber Types Tested | 50/125 µm or 62.5/125 µm |
| Source Type and Wavelengths | LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
| Maximum Length Measurement | 12 km |
| Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length |
| Output Power (Nominal) | ≥ -24 dBm with EF-TRC |
| Output Power Stability3 | ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
| Source Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
| Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
| Power Measurement Uncertainty1, 2 | < +/- 5% +/- 32 pW |
| Measurement Linearity3 | < ± 0.1 dB |
| Re-calibration Period | 1 year |
| Title | Requirement |
| Output Power | >-5 dBm <0 dBm SMF-28 singlemode fiber Continuous wave SC/UPC connector |
| Operating Wavelength | 650 nm nominal |
| Output Modes | Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) |
| Connector Adapter | 2.5 mm universal |
| Laser Safety | Class II CDRH Over operating temperature range |
| Title | Requirement |
| Operating Temperature | -18° C to 45° C |
| Storage Temperature | -30° C to +60° C |
| Operating Relative Humidity % RH without condensation | 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapters |
| Safety | CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2 |
| Pollution Degree | 2 |
| Altitude | Operating: 4,000 m; storage: 12,000 m |
| EMC | EN 61326–1 |
| Multimode module | Singlemode module |
| Wavelengths | 850 nm +/- 10 nm 1300 nm +35/-15 nm |
| Compatible fiber types | 50/125 µm 62.5/125 µm |
| Event dead zone 1 | 850 nm: 0.5 m typical 1300 nm: 0.7 m typical |
| Attenuation dead zone 2 | 850 nm: 2.5 m typical 1300 nm: 4.5 m typical |
| Dynamic range 3, 5, 6 | 850 nm: 28 dB typical 1300 nm: 30 dB typical |
| Max distance range setting | 40 km |
| Distance measurement range 4, 5, 7, 8, 9, 10 | 850 nm: 9 km 1300 nm: 35 km |
| Reflectance range 4, 5 | 850 nm: -14 dB to -57 dB (typical) 1300 nm: -14 dB to -62 dB (typical) |
| Sample resolution | 3 cm to 400 cm |
| Pulse widths (nominal) | 850 nm: 3, 5, 20, 40, 200 ns 1300 nm: 3, 5, 20, 40, 200, 1000 ns |
| Test time (per wavelength) | Auto setting: 5 sec (typical) |
| Quick test setting: 2 sec (typical) | Quick test setting: 5 sec (typical) |
| Best resolution setting: 2 to 180 sec | Best resolution setting: 5 to 180 sec |
| FaultMap setting: 2 sec (typical), 180 sec (max) | FaultMap setting: 10 sec (typical), 180 sec (max) |
| DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) | DataCenter OTDR setting: 20 sec (typical), 40 sec (max) |
| Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec | Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
- Versiv Mainframe & Remote
- (2) DSX-8000 CableAnalyzer modules
- (2) CertiFiber Quad OLTS modules
- OptiFiber Quad OTDR module
- Set of Cat 8/Class I Permanent Link Adapters
- Set of Cat 8/Class 1 Channel Adapters
- (2) Headsets
- (2) Hand Straps
- (2) Shoulder Straps
- Hard sided Carry Case
- USB Interface Cable
- Versiv Open Source Software CD
- (2) AC Chargers
- (2) Universal Couplers
- (2) AxTalk Terminators
- (2) Quick Clean Cleaners (1.25/2.50 mm)
- SC/SC Simplex adapters
- 2 SC/LC Multimode Launch Cables—50 µm
- 2 SC/LC Singlemode Launch Cable—9 µm
- USB Fiber Inspection Video Probe with 4 Tips
- (2) LC/LC Simplex Adapter
- SC/LC EF-Compliant MM TRC Kit 50 µm
- SC/LC SM TRC Kit
- TRC Carry Case
- Statement of Calibration
- Getting Started Guides
- 1 Year of Gold Support from Fluke Networks










Reviews
There are no reviews yet.