Amprobe ACDC-100 TRMS 1000A AC/DC Digital Clamp Meter

$173.00
In Stock
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: AMPROBE-ACDC-16767
Category:
Brand:

Description

Technical Specifications

Specification Name Value
Clamp Meters/Clamp Meters Template True RMSYesMaximum Current AC800 AMaximum Current DC1000 AMaximum Voltage AC600 VMaximum Voltage DC600 VMaximum Conductor Size2 INResistanceYesCapacitanceYesAuto Ranging/ManualBothIn-Rush CurrentYes
Test Equipment General Attributes Unique FeaturesRelative Zero Mode, Third Hand Test Probe HolderWarranty1 YEARSWarranty Details1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling
Additional Info/Comments Line splitter (Energizer), 3000A AC Flexible Clamp-on Attachment, Single Input Thermocouple Temperature Attachment, Test Lead Kit
Product Weight 290 GRAMS (0.639 LBS)
Product Height 40 MM (1.57 IN)
Product Length 227 MM (8.94 IN)
Product Width 78 MM (3.07 IN)
Data Logging No
Calibration Included Factory Calibration
Battery Type AAA
Power Supply Voltage Battery Powered
Country of Origin Taiwan
Shipping Height 3.50 IN
Shipping Length 12.00 IN
Shipping Width 7.25 IN
Display 3-3/4 digits 4000 counts LCD display
Update Rate 3 per second nominal
Polarity Automatic
Low Battery Below approx. 2.4V
Operating Temperature 0C to 40C
Relative Humidity Maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C
Altitude Operating below 2000m
Storage Temperature -20C to 60C, 80% R.H. (with battery removed)
Temperature Coefficient nominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified
Sensing True RMS
Safety Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC.
Transient protection 6.5kV (1.2/50?s surge) for all models
Pollution degree 2
E.M.C. Meets EN61326-1
Clamp-on jaws DC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms
Power Supply standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
Power Consumption typical 11mA for ACA/DCA and 2.9mA for other functions
APO Timing Idle for 30 minutes
APO Consumption typical 190?A
Dimension L227mm X W78mm X H40mm
Weight 290 gm approx
Jaw opening & Conductor diameter 50mm max

Electrical Specifications

Specification Name Value
Accuracy Accuracy is ?(% reading digits + number of digits) or otherwise specified, at 23? ? 5? & less than 75% R.H.
DC Voltage 400.0 mV0.3% + 3d
AC Voltage 50Hz ~ 500Hz 400.0mV 1)4.0% + 4d
Resistance 400.0O0.8% + 6d
Audible Continuity Tester Open Circuit Voltage:: 0.4VDC typical
Diode Tester Open Circuit Voltage: Test Current (Typical)
Capacitance 500.0nF, 5.000?F, 50.00?F, 500.0?F, 3000?F 1)3.5% + 6d2) 3)
DC Current (Clamp-on) 400.0A 0.0A ~ 400.0A1.5% + 4d 1) 2)

Amprobe ACDC-100 TRMS 1000A AC/DC Digital Clamp Meter Specs

Clamp Meters/Clamp Meters TemplateTrue RMSYesMaximum Current AC800 AMaximum Current DC1000 AMaximum Voltage AC600 VMaximum Voltage DC600 VMaximum Conductor Size2 INResistanceYesCapacitanceYesAuto Ranging/ManualBothIn-Rush CurrentYes
Test Equipment General AttributesUnique FeaturesRelative Zero Mode, Third Hand Test Probe HolderWarranty1 YEARSWarranty Details1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling
Additional Info/CommentsLine splitter (Energizer), 3000A AC Flexible Clamp-on Attachment, Single Input Thermocouple Temperature Attachment, Test Lead Kit
Product Weight290 GRAMS (0.639 LBS)
Product Height40 MM (1.57 IN)
Product Length227 MM (8.94 IN)
Product Width78 MM (3.07 IN)
Data LoggingNo
Calibration IncludedFactory Calibration
Battery TypeAAA
Power Supply VoltageBattery Powered
Country of OriginTaiwan
Shipping Height3.50 IN
Shipping Length12.00 IN
Shipping Width7.25 IN
Display3-3/4 digits 4000 counts LCD display
Update Rate3 per second nominal
PolarityAutomatic
Low BatteryBelow approx. 2.4V
Operating Temperature0C to 40C
Relative HumidityMaximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C
AltitudeOperating below 2000m
Storage Temperature-20C to 60C, 80% R.H. (with battery removed)
Temperature Coefficientnominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified
SensingTrue RMS
SafetyMeets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC.
Transient protection6.5kV (1.2/50?s surge) for all models
Pollution degree2
E.M.C.Meets EN61326-1
Clamp-on jawsDC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms
Power Supplystandard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
Power Consumptiontypical 11mA for ACA/DCA and 2.9mA for other functions
APO TimingIdle for 30 minutes
APO Consumptiontypical 190?A
DimensionL227mm X W78mm X H40mm
Weight290 gm approx
Jaw opening & Conductor diameter50mm max
AccuracyAccuracy is ?(% reading digits + number of digits) or otherwise specified, at 23? ? 5? & less than 75% R.H.
DC Voltage400.0 mV0.3% + 3d
AC Voltage 50Hz ~ 500Hz400.0mV 1)4.0% + 4d
Resistance400.0O0.8% + 6d
Audible Continuity TesterOpen Circuit Voltage:: 0.4VDC typical
Diode TesterOpen Circuit Voltage: Test Current (Typical)
Capacitance500.0nF, 5.000?F, 50.00?F, 500.0?F, 3000?F 1)3.5% + 6d2) 3)
DC Current (Clamp-on) 400.0A0.0A ~ 400.0A1.5% + 4d 1) 2)

Reviews

There are no reviews yet.

Be the first to review “Amprobe ACDC-100 TRMS 1000A AC/DC Digital Clamp Meter”

Your email address will not be published. Required fields are marked *