Rigol M300 configuring a flexible automated tracking mainframe, this modular acquisition engine records high-accuracy electrical signals inside production quality control stations.

  • 300V terminal protection isolates internal components.
  • 10MΩ standard input impedance minimizes loading.
  • 1.000000A top direct current range registers.
  • 140 dB common mode rejection isolates.
  • 200.0000mV low voltage span reads microvolts.
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Rigol-M300
Brand:

Rigol M300 Data Acquisition Switch System Specs

FunctionRange [2]
DC Voltage200.0000mV
2.000000V-
20.00000V-
200.0000V-
300.000V-
DC Current200.0000µA
2.000000mA<0.25V
20.00000mA<0.07V
200.0000mA<0.7V
1.000000A<0.12V
Resistance [4]200.0000Ω
2.000000kΩ1mA
20.00000kΩ100µA
200.0000kΩ10µA
1.000000MΩ2µA
10.00000MΩ200nA
200nA || 10MΩ0.300 + 0.010
Input Impedance200mV, 2V, 20V ranges: 10MΩ or >10GΩ   (For these ranges, input beyond ±26 V are clamped through 106 kΩ)
Input Protection300V
Input Offset Current50pA, at 25°C , typical
CMRR (common mode   rejection ratio)140 dB for 1 kΩ unbalanced resistance in LO lead, ±300 VDC peak maximum.
Measurement Method4-wire or 2-wire resistance   Current source referenced to LO input
Open-circuit VoltageLimited to <10 V
Max. Lead Resistance   (4-wire)10% of range per lead for 200 Ω and 2 kΩ ranges, 1 kΩ per lead on all other ranges
Input Protection300V on all ranges
Offset CompensationAvailable on 200 Ω, 2 kΩ and 20 kΩ ranges.
Shunt Resistor100 Ω for 200 uA, 2 mA
FunctionRange [2]
True   RMS AC   Voltage [4]200.0000mV
5Hz-10Hz0.35 + 0.03
10Hz-20kHz0.04 + 0.03
20kHz-50kHz0.10 + 0.05
50kHz-100kHz0.55 + 0.08
100kHz- 300kHz4.00 + 0.50
2.000000V3Hz-5Hz
5Hz-10Hz0.35 + 0.02
10Hz-20kHz0.04 + 0.02
20kHz-50kHz0.10 + 0.04
50kHz-100kHz0.55 + 0.08
100kHz- 300kHz4.00 + 0.50
2.000000V3Hz-5Hz
5Hz-10Hz0.35 + 0.02
10Hz-20kHz0.04 + 0.02
20kHz-50kHz0.10 + 0.04
50kHz-100kHz0.55 + 0.08
100kHz-300kHz4.00 + 0.50
20.00000V3Hz-5Hz
5Hz-10Hz0.35 + 0.03
10Hz-20kHz0.04 + 0.04
20kHz- 50kHz0.10 + 0.05
50kHz-100kHz0.55 + 0.08
100kHz-300kHz4.00 + 0.50
200.0000V3Hz-5Hz
5Hz-10Hz0.35 + 0.02
10Hz-20kHz0.04 + 0.02
20kHz-50kHz0.10 + 0.04
50kHz-100kHz0.55 + 0.08
100kHz-300kHz4.0 + 0.50
300.000V3Hz-5Hz
5Hz-10Hz0.35 + 0.02
10Hz-20kHz0.04 + 0.02
20kHz-50kHz0.10 + 0.04
50kHz-100kHz0.55 + 0.08
100kHz-300kHz4.0 + 0.50
True   RMS AC   Current [6]200.0000µA
5Hz-10Hz0.35 + 0.06
10Hz-5kHz0.15 + 0.06
5kHz-10kHz0.35 + 0.70
2.000000mA3Hz-5Hz
5Hz-10Hz0.30 + 0.04
10Hz-5kHz0.12 + 0.04
5kHz-10kHz0.20 + 0.25
20.00000mA3Hz-5Hz
5Hz-10Hz0.35 + 0.06
10Hz-5kHz0.15 + 0.06
5kHz-10kHz0.35 + 0.70
200.0000mA3Hz-5Hz
5Hz-10Hz0.30 + 0.04
10Hz-5kHz0.10 + 0.04
5kHz-10kHz0.20 + 0.25
1.000000A3Hz-5Hz
5Hz-10Hz0.35 + 0.06
10Hz-5kHz0.15 + 0.06
5kHz-10kHz0.35 + 0.70
5Hz-10Hz0.35 + 0.08
10Hz-5kHz0.15 + 0.08
Measurement MethodAC-coupled True-RMS - measure the ac component of input with up to 300 V DC bias on any range.
Crest Factor≤ 5 at full range
Input Impedance1 MΩ ± 2%, in parallel with <150 pF capacitance on any range
Input Protection300 V rms on all ranges
AC Filter BandwidthSlow: 3 Hz - 300 kHz
CMRR (common mode   rejection ratio)70 dB, for the 1 kΩ unbalance in LO lead, <60 Hz common mode signal frequency, ±500 VDC peak   maximum.
Measurement MethodDirect coupled to the fuse and shunt; AC-coupled True RMS measurement (measure the AC component).
Crest Factor≤ 3 at full range
Max. InputDC + AC current peak value <300% of range. Current with DC current component <10 A rms.
Shunt Resistor100 Ω for 200 uA, 2 mA
FunctionRange
Frequency,   Period200mV-300V
5 Hz-10 Hz0.04
10 Hz-40 Hz0.02
40 Hz-300 kHz0.005
300 kHz-1 MHz0.005
FrequencyGate Time (Resolution)
1s(0.1ppm)0.1s(1ppm)
3 Hz-5Hz0
5 Hz-10Hz0
10 Hz-40Hz0
     
  • Power Cord Conforming to the Standard of the Country
  •  
  • USB Cable
  •  
  • Mixed-interface Separator Line
  •  
  • M300 Series Standard Control and Data Analysis PC Software
  •  
  • Four Spare Fuses  
        
    • 2 AC, 250 V, T3.15 A fuses
    •   
    • 2 AC, 250 V, T250 mA fuses
    •  
     
  •  
  • Quick Guide
  •  
  • NIST calibration certificate for the M300

Reviews

There are no reviews yet.

Be the first to review “Rigol M300 Data Acquisition Switch System”

Your email address will not be published. Required fields are marked *