Fluke 6531-7M Electronic Deadweight Tester Kits
$24,816.00
In Stock
In Stock
Fluke 6531-7M Electronic Deadweight Tester Kits Specs
| Power requirements | To RPM4-E-DWT: 12 V dc 1.2 A To ac to dc power supply: 100 V ac to 240 V ac, 50/60 Hz |
| Operating temperature range | 10 ?C to 40 ?C (50 ?F to 104 ?F) |
| Storage temperature range | -20 ?C to 70 ?C (-4 ?F to 158 ?F) (must be above freezing point and below boiling point of test medium) |
| Relative operating humidity | 0 % to 70 % |
| Relative storage humidity | 0 % to 100 % |
| Weight | E-DWT with 1 Q-RPT: 12 kg (26 lb) approximate E-DWT with 2 Q-RPTs: 14 kg (30 lb) approximate |
| Dimensions | E-DWT footprint: 41.4 cm W x 37.1 cm D (16.3 in x 14.6 in) E-DWT height: 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height |
| Pressure range | Up to 200 MPa (30k psi), depending on configuration |
| Operating medium | All 6531 and 6532 E-DWT Kits are shipped dry, standard preparation. Can be filled with di-ethyl-hexyl sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol and distilled water or mineral oil. |
| Reservoir capacity | 300 cc (18 in 3 ) |
| Variable volume displacement | 3 cc (0.18 in 3 ), 200 MPa (30 000 psi) maximum |
| Filling and priming pump displacement | 3.7 cc (0.23 in 3 ) |
| TEST pressure connection | DH500 female, 200 MPa (30k psi) maximum working pressure. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. Adapter maximum working pressure is 140 MPa (20k psi). Note: DH500 is a gland and collar type fitting for 6 mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc. |
| Pressure limits | Maximum working pressure: Range of RPM4-E-DWT monitor?s Hi Q-RPT Maximum priming pump pressure: 700 kPa (100 psi) Maximum working pressure with Lo Q-RPT selected: Range of RPM4-E-DWT monitor?s Lo Q-RPT |
| Communication ports | RS-232 (COM1, COM2) |
| Warm up time | 15 minute temperature stabilization recommended from cold power up |
| Normal operating temperature range | 10 ?C to 40 ?C (50 ?F to 104 ?F) |
| Resolution | Default: 0.01 % of active range User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger |
| Precision 1 | ? 0.018 % of reading or 0.0018 % of Q-RPT span, whichever is greater |
| Predicted Stability 2 | One year: ? 0.0075 % of reading Two year: ? 0.015 % of reading |
| Measurement uncertainty 3 | One year: ? 0.02 % of reading or 0.002 % of Q-RPT span, whichever is greater Two year: ? 0.025 % of reading or 0.0025 % of Q-RPT span, whichever is greater |
- E-DWT-H Electronic Deadweight Tester with power supply and operating manual
- Vacuum liquid fill kit
- Test station quick-mount fitting
- NPT adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
- BSP adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
- Metric adapters: M20 x 1.5 and M14 x 1.5
- ISO 17025 Accredited Calibration Certificate









Reviews