Fluke Networks MFTK-MM850-SM1310 Optical Power Meter and Fiber Test Kit
$16,439.00
In Stock
In Stock
Fluke Networks MFTK-MM850-SM1310 Optical Power Meter and Fiber Test Kit Specs
| Operating temperature | -10ºC to +50ºC |
| Storage temperature | -20ºC to +50ºC |
| Operating humidity | 95% (10ºC to +35ºC) non-condensing 75% (35ºC to +45ºC) non-condensing Uncontrolled <10ºC |
| Operating altitude | 4,000 m |
| Storage altitude | 12,000 m |
| Vibration | Random 2 G, 5 Hz to 500 Hz |
| Detector type | InGaAs |
| Calibrated wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
| Measurement range | 0 dBm to -50 dBm |
| Test time | 6 seconds |
| Power measurement linearity | ±0.1 dB2 |
| Power measurement uncertainty | ±0.35 dB2 |
| Power measurement repeatability | < 0.10 dB2 |
| Display resolution, dB or dBm | 0.01 |
| Power display units | dBm, mW, µW |
| User-selectable limit for loss | 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB |
| Auto wavelength detection | Yes |
| Polarity detection | Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities |
| 2 kHz detection | Yes |
| Record storage | 3000 records, one fiber per record (250 12-fiber cables) |
| External interface | USB 2.0, full speed |
| Optical connector | MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover. |
| Power requirement | 2 AA alkaline batteries |
| Battery life3 | 30 hours (typical) |
| Automatic power-off | 10, 20, 30, or 60 minutes (can be disabled by the user) |
| Low battery warning | Low battery icon blinks |
| Size | 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm) |
| Weight | 10.9 oz (309 g) |
| Emitter type | Laser |
| Wavelength | 1310 nm ±20 nm |
| Spectral width (FWHM) | 2 nm typical, 5 nm maximum |
| Minimum output power | ≥ -1 dBm |
| Power output stability | ±0.25 dB over 8 hours5 |
| Laser safety | IEC 60825-1:Class 1 |
| Optical connector | MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 9 µm fibers, APC only. Connector has a self-closing, protective cover. |
| Modes | 2 kHz modulated, auto wavelength/td> |
| Power requirement | 2 AA alkaline batteries |
| Battery life6 | >30 hours (typical) |
| Automatic power-off | 10, 20, 30, or 60 minutes (can be disabled by the user) |
| Low battery warning | Low battery icon blinks |
| Size | 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm) |
| Weight | 11.4 oz (323 g) |
- MultiFiber Pro Power Meter
- 850 nm LED light source
- 1310 nm laser light source
- Multimode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned)
- Singlemode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned)
- 2 MPO adapters
- 2 APC MPO adapters
- Magnetic Strap Attachments
- Carrying case











Reviews