Parker icountPDR-Custom – Online Particle Detector, Robust Construction, No Display, Configure Model
In Stock
Parker icountPDR-Custom - Online Particle Detector, Robust Construction, No Display, Configure Model Specs
| Product start-up time | 5 seconds minimum |
| Measurement period | 5–180 seconds |
| Reporting interval | 0–3600 seconds via RS232 communication |
| Principle of operation | Laser Diode optical detection of actual particulates |
| International codes | ISO 7 – 22, NAS 0 – 12 |
| Calibration | By recognized online methods confirmed by the relevant ISO procedures: MTD – via a certified primary ISO 11171 automatic particle detector using ISO 11943 principles, with particle distribution reporting to ISO 4406:1996 |
| Recalibration | Contact Parker Hannifin |
| Working pressure | 2–420 bar (30–6000 PSI) |
| Flow range through icountPDR | Note : Flow may be bi-directional 40–140 ml/min (optimum flow 60 ml/min) (0.01 – 0.04 USGPM (optimum flow 0.016 USGPM)) |
| Online flow range via System 20 sensors | Size 0 = 6 to 25 l/min (2–7 USGPM) Size 1 = 24 to 100 l/min (6–26 USGPM) Size 2 = 170 to 380 l/min (45–100 USGPM) |
| Ambient storage temperature | –40°C to +80°C (–40°F to +176°F) |
| Environment operating temperature | -30°C to +60°C (–22°F to 140°F) |
| Fluid operating temperature | +5°C to +80°C (+41°F to 176°F) |
| Computer compatibility | Parker recommends the use of a 9-way D-type connector. This can be connected to a USB port using a USB-serial adaptor. Note that these connectors/adaptors are NOT supplied with icountPDR units: contact Parker Hannifin for advice. |
| Moisture sensor calibration | ±5% RH (over compensated temperature range of +10ºC to +80ºC; +50ºF to +176ºF) |
| Operating humidity range | 5% RH to 100% RH |
| Moisture sensor stability | ±0.2% RH typical at 50% RH in one year |
| Power requirement | Regulated 9–40Vdc |
| Current rating | Typically 120mA |
| Certification | IP69K rating |
| Variable current | 4–20mA |
| Variable voltage | 0–5Vdc, 0–3Vdc (user selectable) |
| CAN-bus | to SAE J1939 (e.g. Parker IQAN) |
| Moisture sensor | Linear scale within the range 5% RH to 100% RH |







Reviews