Thermo Scientific Orion Versa Star VSTAR93 – Orion Versa Star Pro Meter Kit

$4,097.00
In Stock

Oakton VSTAR93 Benchtop multiparameter meter with 4 customizable channels, color graphic LCD, and -2.000 to 20.000 pH range supports laboratory analytical testing.

  • Four channels support configuration.
  • 3000 mS/cm conductivity measures samples.
  • Color LCD displays measurements.
  • 2000 data points retain records.
  • USB and RS232 export data.
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Thermo-Scientific-Orion-Versa-Star-VSTAR93
Brand:

Thermo Scientific Orion Versa Star VSTAR93 - Orion Versa Star Pro Meter Kit Specs

Range (pH)-2.000 to 20.000pH
Resolution (pH)0.1, 0.01, 0.001pH
Accuracy (pH)±0.002pH
Range (mV)±2000.0mV
Range (Relative mV)±2000.0mV
Range (ORP)±2000.0mV
Resolution (mV)0.1mV
Accuracy (mV)±0.2 mV or ±0.05% of reading whichever is greater
Range (ISE)0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Resolution (ISE)0.0001 minimum, 1 to 4 significant digits (user selectable)
Accuracy (ISE)±0.2 mV or ±0.05% of reading whichever is greater
Advanced ISE FunctionsNon-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition and subtraction, double known addition and subtraction, single analyte addition and subtraction
Isopotential Point7.000pH (adjustable), 1.000 ISE (adjustable)
Range (Conductivity)0.001 µS/cm to 3000 mS/cm
Resolution (Conductivity)0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Conductivity)0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS)0.001 to 200.0 ppm
Resolution (TDS)0.001 ppm minimum, auto ranging up to 4 significant digits
Accuracy (TDS)0.5% of reading ±1 digit
TDS Factor RangeLinear (0.02 to 9.99)
Range (Salinity)0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity)0.01 psu or 0.01 ppt minimum, auto ranging
Accuracy (Salinity)0.5% of reading ±1 digit
Salinity Measurement ModesPractical salinity (psu) or natural sea water (ppt)
Range (Resistivity)2 ohm to 100.0 meg-ohm
Resolution (Resistivity)1 ohm or 0.1 meg-ohm, auto ranging
Accuracy (Resistivity)0.5% of reading ±1 digit
Cell Constant0.001 to 199.9cm-1
Temperature CompensationLinear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (Metric) Reference5, 10, 15, 20, 25°C
Range (Polarographic DO)0.00 to 90.00mg/L
Resolution (Polarographic DO)0.01, 0.1mg/L
Accuracy (Polarographic DO)±0.2mg/L or ±2% of reading, whichever is greater
Range (RDO)0.00 to 50.00mg/L
Resolution (RDO)0.01, 0.1mg/L
Accuracy (RDO)±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L
Percent Saturation Range (Polarographic DO)0.0 to 600.0 % saturation
Percent Saturation Resolution (Polarographic DO)0.1, 1 % saturation
Percent Saturation Relative Accuracy (Polarographic DO)±2 % saturation or ±2% of reading whichever is greater
Percent Saturation Range (RDO)0.0 to 500.0 % saturation
Percent Saturation Resolution (RDO)0.1, 1 % saturation
Percent Saturation Relative Accuracy (RDO)±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Barometric Pressure Correction400 to 850mmHg, automatic using built-in barometer or manual entry
Pressure Range400 to 850mmHg
Pressure Resolution0.1mmHg
Accuracy (Barometer)±6mmHg
Salinity Factor0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
CalibrationpH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option, dissolved oxygen and temperature
Calibration Points (pH)1 to 6
Calibration Points (ISE)1 to 6
Calibration Points1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity)Up to 6
Calibration ModesWater-saturated air, air-saturated water, manual (Winkler titration), zero point
Range (Temperature)-5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature)0.1°C, 0.1°F
Accuracy (Temperature)±0.1°C
Temperature SelectionManual or automatic with ATC temperature probe
Temperature Probe Calibration1 point temperature offset calibration
Channels4 - customizable with modules
Display TypeColor graphic LCD with user-customizable options
Backlight OptionYes
KeypadNumeric with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement ModespH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature; conductivity, TDS, salinity or resistivity with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
StabilitySelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management DetailsTransfer single, range or all data points to printer or computer
Data Points2000 with date and time stamp
Log Function TypeAutomatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
MemoryNon-volatile memory preserves data log, calibration log and meter settings
Alarm OutputSet point alarm, high/low limit alarm, calibration due alarm
Methods10 per channel
LanguagesEnglish, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Inputs2 BNC (pH or ISE), 2 x 8-pin Mini-DIN (temperature), 2 reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
OutputsUSB (2), RS232
Power SupplyUniversal AC adapter (included)
AC AdapterUniversal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
IP RatingIP-54
Certifications/ComplianceCE, TUV 3-1, FCC Class A
Temperature (English) Operating41° to 113°F (ambient)
Temperature (Metric) Operating5° to 45° C (ambient)
Relative Humidity Range5 to 85 %, non-condensing
Dimensions (L x W x H)28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Weight (Metric)1.2kg, modules add 0.2kg each
Weight (English)2.5 lb., modules add 0.5 lb. each
Warranty3 year meter and module warranty
Power RatingDC input: 9VDC, 1A
     
  • Includes Versa Star Pro meter
  •  
  • Includes Two VSTAR-ISE pH/ISE modules
  •  
  • Includes VSTAR-CND conductivity module
  •  
  • Includes VSTAR-RD RDO/DO module
  •  
  • Includes 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode
  •  
  • Includes 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor
  •  
  • Includes 083005MD Orion polarographic dissolved oxygen sensor
  •  
  • Includes 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit
  •  
  • Includes 011007 Orion 1413µS conductivity standard
  •  
  • Includes 080513 DO maintenance kit 
  •  
  • Includes BOD adapter/funnel/stirrer
  •  
  • Includes Electrode stand
  •  
  • Includes Universal power adapter
  •  
  • Includes Literature CD
  •  
  • Includes Printed quick start guide
  •  
  • Includes Computer interface cable and meter test certificate

Reviews

There are no reviews yet.

Be the first to review “Thermo Scientific Orion Versa Star VSTAR93 – Orion Versa Star Pro Meter Kit”

Your email address will not be published. Required fields are marked *