SCI 446 – AC/DC Hipot (5kV/6kV) with Insulation Resistance and Ground Bond Testing
$2,079.00
In Stock
In Stock
SCI 446 - AC/DC Hipot (5kV/6kV) with Insulation Resistance and Ground Bond Testing Specs
| Type | Ground Bond Tester |
| Voltage | 100 - 120Vac / 200 - 240Vacą10% Auto Range |
| Frequency | 50/60Hz ą 5% |
| Fuse | 10A / 250Vac Slow-Blow |
| Range | Resolution |
| Output Voltage, K VAC | 0-5.00 |
| Output Frequency | 0Hz/60Hz ± 0.1% , User Selection |
| Output Waveform | Sine Wave, Crest Factor = 1.3 - 1.5 and output voltage > 300V |
| Output Regulation, Vrms | ± (1% of output + 5V), From no load to full load and Low Line to High Line (combined regulation) |
| Hi-Limit AC current, mA | 0.10-20.00 |
| Lo-Limit AC current, mA | 0.00-20.00 |
| Ramp Time, second | 0.2-180.0 |
| Dwell Time, second | 0, 0.2 - 60.0 (0=continuous) |
| Output Voltage, KVDC | 0 -6.00 |
| DC Output Ripple, Vrms | <5 % (6KV / 5mA at Resistive Load) |
| Hi-Limit DC current, mA | 0.02 - 5.00 |
| Lo-Limit DC current, mA | 0.00 - 5.00 |
| Ramp Time, second | 0.2 - 180.0 |
| Dwell Time, second | 0, 0.2 - 60.0 (0=continuous) |
| Discharge Time | < 50 msec for no load, < 200 msec for capacitor load |
| Maximum Capacitive LoadDC Mode | 1μF < 1KV 0.08μF < 4KV 0.75μF < 2KV 0.04μF < 5KV 0.5μF < 3KV 0.015uF < 6KV |
| Range | Resolution |
| Output Voltage, VDC | 100 - 1000 |
| Hi-Limit resistance, MΩ | 0, 1 - 1000 (0 = OFF) |
| Lo-Limit resistance, MΩ | 1 - 1000 |
| Ramp Time , second | 0.1 or 2.0 |
| Delay Time, second | 0, 0.5 - 999.9(0=continuous) |
| Output AC Current, A | 1.0 – 40.0 |
| Output AC Voltage, V | 8V(Fixed) |
| Output Frequency, Hz | 50Hz/60Hz ± 0.1%, User Selectable |
| Maximum Loading | 1.0–10.0A/0–600mΩ,10.1–30.0A/0–200mΩ,30.1–40.0A/0–150mΩ |
| Offset, mΩ | 0-100 |
| HI and LO-Limit Resistance, mΩ | 0 - 150(30.1-40.0A) |
| Fix Ramp Timer, second | 0.4 |
| Dwell Timer, second | 0, 0.1 - 240.0(0 = continuous) |
| Memories | Allows storage of up to 20 different test programs and a single step mode |
| Remote I/O | Input: Test, Reset, Interlock & Recall Memory 1 – 6 Output: Pass, Fail, Test-in-Process |
| Interface | USB (Optional) |
| Security | Lockout capability to avoid unauthorized access to test set-up programs |
| Calibration | Software and adjustments made through the front panel |
| Dimensions | 280mm(W) ×89mm(H) × 400 mm(D) |
| Weight | 18 lbs (8kg) |
- 125-013-001 - Power Cord (10A) 6ft.
- 99-10783-01 - Fuse 10A Slow Blow 20mm
- 99-10040-01 - Interlock Connector Male
- 99-10866-01 - Ground Bond Test Lead
- 99-10865-01 - Ground Bond Return Lead
- 102-055-913 - High Voltage Lead 6ft.
- 99-10797-01 - USB Cable
- NIST Traceable Calibration Certificate







Reviews
There are no reviews yet.