Vitrek 953i – 11KVDC 6KVAC/IR/LR Electrical Safety Compliance Analyzer

$4,756.00
In Stock
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Vitrek-953i
Category:
Brand:

Vitrek 953i - 11KVDC 6KVAC/IR/LR Electrical Safety Compliance Analyzer Specs

DC Output Voltage30V to 6500V (951i & 952i)   50V to 11000V (953i,954i & 955i)
Resolution0.1V up to 999.9V, 1V above
Accuracy0.25% + 0.5V ( 1 year 23°C ± 3°)
DC Current Sourcing50mA max, 25mA above 6000V (951i & 952i)   30mA max, 20mA above 6000V, 10mA above   7500V, 5mA above 9000V (953i, 954i, 955i)
Ramp Time0.01 to 9999sec, 0.01sec resolution   or 0.1 to 50000V/sec, 0.1V/sec resolution
Dwell Time0.02 to 9999 seconds or user terminated, 0.01sec resolution
Discharge25mA max in solid-state constant current discharge mode, selectable same as ramp rate or ramp to next level if next step is DCW, DCez or DCIR
DC Leakage CurrentMeasurement Range: 0 to +/-200mA,
Resolution4 digits (9999 counts) down to 100pico-amp
Accuracy0.25% + 0.5nA + ½ digit ( 1 year 23°C ± 3°)
Min & Max Current limitsSelectable for Ramp and Dwell 100 pico-amps and up
Measurement Period1 power line cycle (50/60Hz)
Insulation Resistance (IR)Test modes include: End on pass reading, end on fail or end on dwell timer
Test Voltage5% Accuracy* Max resistance
500V50GΩ
1000V100GΩ
2500V250GΩ
5000V500GΩ
10000V1TΩ
AC Output Voltage20V to 6000V RMS (951i, 952i, 953i, 954i)   50V to 10,000V RMS (955i)   100V to 30,000V RMS (option AC-30)
Resolution0.1V up to 999.9V, 1V above
Accuracy0.5% + 1.5V (+ 0.01% per Hz above 100Hz)
AC Current Sourcing50mA RMS max (951i, 952i, 953i, 954i)   30mA RMS max , (955i)   200mA RMS with option AC-2 (2KVAC RMS max output)   10mA RMS Max with AC-30 option
Output FrequencyDigitally synthesized, low distortion sinewave   20Hz to 500Hz, standard or AC-2)   40Hz to 500Hz, (955i)   0.1% accuracy, 0.1Hz resolution (1Hz above 99.9Hz)
Ramp Time0 to 9999sec, 0.01sec resolution or 0.1 to 100000V/sec, 0.1V/sec resolution
Dwell Time0.02 to 9999 seconds or user terminated, 0.01sec resolution
Accuracy0.05% + 20mS
Ramp DownSelectable same as ramp time or ramp to next level if next test step is an ACV test type
AC Leakage CurrentMeasurement Range: 0 to +/-200mA RMS
Resolution4 digits (9999 counts) down to 100pico-amps
Accuracy0.5% + 10nA (add 0.005% per Hz above 100Hz) Selectable min & max limits for Ramp & Dwell, from 100 pico amps up Measurement Period: 1 power line cycle (50/60Hz)
Phase MeasurementTotal RMS current, In-phase current, Quadrature current (reactive/out-of-phase)
Accuracy0.01° per Hz, relative to output voltage
AC Insulation ResistanceTest modes include: End on pass reading, end on fail or end on dwell timer
Test Voltage (50/60Hz)10% Accuracy* Max resistance
500V5GΩ
1000V10GΩ
2500V25GΩ
5000V50GΩ
10000V (955i only)100GΩ
Test Current0.1 to 40A RMS, 0.001A resolution
Accuracy0.5% + 5mA accuracy (add 0.005% per Hz above 100Hz)
Test Frequency40Hz to 500Hz
Resolution0.1Hz (1Hz above 99.9Hz) Accuracy: 0.1% accuracy
WaveformDigitally synthesized, low distortion sinewave
Measurement Configuration4-Terminal Kelvin
Compliance Voltage6.5V RMS, may be user limited to a lower level with 0.01V resolution
Resistance Range6.5 ohms at 1A decreasing to 162.5 milli-ohms max at 40A
Max load impedance10 ohms
Ramp Time0 to 9999sec, 0.01sec resolution
Accuracy(1% + 0.1sec) accuracy
Dwell Time0.02 to 9999sec or user terminated, 0.01sec resolution
Accuracy0.05% + 20ms
Ramp DownFast (35mS), same rate as ramp up or may be skipped if next test step is a ground bond test
Voltage SenseRange: 0 to 8 v rms
Resolution4 digits down to 10uV Accuracy: 0.5% + 30uV
Phase MeasurementRMS, In-phase and Quadrature measurements 0.01° per Hz phase relative to test current
Measurement Range0 to 150Kohm (999.9mΩ to 99.99KΩ, 149.9KΩ in 7 ranges)
Resolution4 digits, 100µΩ on 1ohm range
Test Current55mAdc constant current up to ≈ 91Ω, 5VDC constant V above
Accuracy (4-wire)0.5% + 0.002ohm + ½ digit up to 30K ohm   1.5% + ½ digit above 30K ohm   5% + 1 digit from 100K to 150K ohm   Add 20mΩ for 2 -wire
Voltage Measurement0 to ± 8KVDC 6KV RMS AC (951i & 952i)   0 to ± 11KVDC 8KV RMS AC (953i & 954i)   0 to ± 11KVDC 10KV RMS AC ( 955i)
Resolution0.1V, 1 V above 999.9V
DC Accuracy0.25% + 0.5V
AC Accuracy0.5% + 1.5V
Leakage Current0 to ± 200mA DC or RMS AC
Resolution4 digits (9999 counts) down to100pico-amps
DC Accuracy0.25% + 0.5nA
AC Accuracy0.5% + 20nA
Test Results Test Time0.02 to 9999 sec Last, Minimum, Average & Max V& A reading plus arc current
Test WaveformTrapezoidal (Selectable positive polarity, negative polarity or bi-polar)
Ramp Up/Down Time1ms (0.5ms for option AC2) to 30mS with 0.1ms resolution
Dwell Time1ms (0.5ms for option AC2) to 30mS with 0.1ms resolution
Test Voltage50V to 8000V (20V to 2750V with option AC-2)
Resolution0.1V up to 999.9V, 1V above
Accuracy0.25% + 1.5V
Test Lead Safety SenseTLSS™ Technology continuously verifies that test leads are properly connected prior to and during HV, 4-wire Low Ohms and Ground Bond testing
Arc Detection SensitivityUser selectable 3 microseconds to 30 microseconds.
Dwell Time AccuracyAccuracy: 0.05% + 20mS
RS232 InterfaceDigital I/O, VICL: Vitrek auxiliary unit control loop   Remote Interface Option "IF-3":   GPIB - IEEE-488.2 Subset compatible   RS232C - 1200, 2400, 4800, 9600 Baud rate selectable   Parallel - IBM/Centronics compatible
AccuracyStated specifications are bipolar and apply for one year within 5°C from calibration temperature (20 to 25°C).
Operating Temperature0 C to 50° C
Humidity90% RH, 0 to 40° C
Power115/230 VAC + 10%, 350 VA Max
Dimensions89mm H x 432mm W x 457mm D (3.5" H x 17" W x 18" D)
Weight9Kg (18 lb.) Net / 18Kg (25 lb.) shipping (951i, 953i, 959i)   14Kg (28 lb.) Net / 18Kg (35 lb.) shipping (952, 954i, 955i)
     
  • 11KVDC 6KVAC/IR/LR Electrical Safety Compliance Analyzer
  •  
  • TL-209
  •  
  • Power Cord
  •  
  • Operating Manual
  •  
  • QTPro II-950 45 day free trial
  •  
  • NIST Traceable Calibration Certificate without data

Reviews