Memmert IF30-230V – Incubator I, Forced Air Convection
A forced air convection mechanical concept design parameter dictates the operational framework of this hardware. The Memmert IF30-230V standard incubator provides reliable automated temperature regulation within a space-saving 32L mechanical configuration layout. This entry-level machine leverages a single Pt100 sensor and an adaptive SingleDISPLAY PID-microprocessor controller to track interior energy distribution metrics from +20 to +80 °C safely under a 160 W configuration load, minimizing unexpected diagnostic variations.
Memmert IF30-230V - Incubator I, Forced Air Convection Specs
| Working temperature range | min. 10°C above ambient up to +80°C |
| Setting accuracy temperature | 0.1 °C |
| Temperature | 1 Pt100 sensor DIN class A in 4-wire-circuit |
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian |
| ControlCOCKPIT | SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Calibration | three freely selectable temperature values |
| adjustable parameters | temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime/wintertime |
| Fan | forced air circulation by quiet air turbine, adjustable in 10 % steps |
| Fresh air admixture | adjustment of pre-heated fresh air admixture by air flap control in 10 % steps |
| Vent | vent connection with restrictor flap |
| Documentation | programme stored in case of power failure |
| Programming | AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). |
| Temperature control | adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| Autodiagnostic system | for fault analysis |
| Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
| Internals | 1 stainless steel grid(s), electropolished |
| Works calibration certificate | incl. works calibration certificate for +37°C |
| Door | inner glass door |
| Interior | easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides |
| Volume | 32 l |
| Dimensions | w(A) x h(B) x d(C): 400 x 320 x 250 mm |
| Max. number of internals | 3 |
| Max. loading of chamber | 60 kg |
| Max. loading per internal | 20 kg |
| Dimensions | w(D) x h(E) x d(F): 585 x 704 x 434 mm |
| Housing | rear zinc-plated steel |
| Voltage Electrical load | 230 V, 50/60 Hz approx. 1600 W |
| Voltage Electrical load | 115 V, 50/60 Hz approx. 800 W |
| Set Up | The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
| Altitude of installation | max. 2,000 m above sea level |
| Ambient temperature | +5 °C to +40 °C |
| Humidity rh | max. 80 %, non-condensing |
| Overvoltage category | II |
| Pollution degree | 2 |
| Net weight | approx. 48 kg |
| Gross weight carton | approx. 64 kg |