Fluke 1507 - Insulation Resistance Tester Specs
| Accuracy | Range: 600.0 V Resolution: 0.1 V 50 Hz to 400 Hz ± (% of Rdg + Digits): ±(2 % + 3) |
| Input Impedance | 3 MΩ (nominal), < 100 pF |
| Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at dc, 50 or 60 Hz |
| Overload Protection | 600 V rms or dc |
| Range/Resolution | 20.00 Ω 0.01 Ω 200.0 Ω 0.1 Ω 2000 Ω 1.0 Ω 20.00 kΩ 0.01 kΩ |
| Accuracy | ±(1.5% + 3) |
| Overload Protection | 2 V rms or dc |
| Open Circuit Test Voltage | > 4.0 V, < 8 V |
| Short circuit current | > 200.0 mA |
| Measurement Range | 0.01 MΩ to 2000 MΩ |
| Test voltages | 500 V, 1000V |
| Test Voltage Accuracy | + 20 %, - 0 % |
| Short circuit current | 1 mA nominal |
| Auto Discharge | Discharge time < 0.5 second for C = 1 µF or less |
| Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test |
| Maximum Capacitive Load | Operable with up to 1 µF load |
| Measure Accuracy | 50 V: ±(3 % + 5) 100 V: ±(3 % + 5) 250 V: ±(1.5 % + 5) 500 V: ±(1.5 % + 5) 1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
| Maximum voltage applied to any terminal: | 600 V ac rms or dc |
| Storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
| Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) |
| Temperature Coefficient | 0.05 x (specified accuracy) per °C for temperatures 28 °C ( 82 °F) |
| Relative Humidity | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) |
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
| Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
| Electromagnetic compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
| Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
| Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
| Batteries | Four AA batteries (NEDA 15A or IEC LR6) |
| Battery life | Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
| Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
| Weight | 550 g (1.2 lb) |
| IP Rating | IP40 |
| Altitude | Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operating (storage): 12,000 m |
| Over-range capability | 110% of range |
| Included accessories | TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
- Fluke 1507
- Remote probe
- Test leads
- Test probes
- Alligator clips
- User documentation