Fieldpiece JL3KM2 – Job Link System Dual Port Manometer Probe Kit
$148.00
In Stock
In Stock
Fieldpiece JL3KM2 - Job Link System Dual Port Manometer Probe Kit Specs
| Minimum Device Requirement | BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 |
| Compatible Media | Dry, non-corrosive gas |
| Pressure Port | Tube connector for flexible tubing (4.5 to 8mm ID) |
| Units of Measure | inWC, mmWC, mbar, psi, Pa |
| Accuracy and Ranges | inWC: ±0.02 on 0.00 to ±2.00 (±1.5% FS on 2.00 to ±60.00); mmWC: ±0.5 on 0.0 to ±51.0 (±1.5% FS on 51.0 to ±1500.0); mbar: ±0.05 on 0.00 to ±5.00 (±1.5% FS on 5.00 to ±150.00); psi: ±0.001 on 0.000 to ±0.072 (±1.5% FS on 0.072 to ±2.165); Pa: ±5 on 0 to 498 (±1.5% FS on 498 to ±14930) |
| Maximum Overload Pressure | 305 inWC (11 psi) |
| Battery Type | 2 x AAA, NEDA 24A, IEC LR03 |
| Battery Life | 150 hours typical alkaline. LED slow-blinks red when battery replacement is needed. |
| Auto Power Off | 2 hours (APO can be disabled) |
| Wireless Range | 350 feet (107 meters) line of sight. Obstructions affect distance. |
| Radio Frequency | 2.4 GHz |
| Operating Environment | -10°F to 122°F (-23°C to 50°C) at <75% |
| RH Storage Temperature | -10°F to 140°F (-23°C to 60°C) at <80% RH (with batteries removed) |
| Temperature Coefficient | 0.1 x (specified accuracy) per 1.8°F (-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to 50°C) |
| Weight | 0.30 lbs (137 g) |
- (2) Manometer Probe
- (2) Static Pressure Probe and Hose
- (2) Brass Screw Fitting with Extra Hose
- (2) Slide Gas Adapter
- Padded Case








Reviews
There are no reviews yet.