Megger DLRO10HD – Digital Low Resistance Ohmmeter, 10 Amp
$3,532.00
In Stock
In Stock
Megger DLRO10HD - Digital Low Resistance Ohmmeter, 10 Amp Specs
| Test Current | Resistance Range |
| 0.1 mA | 0 to 2500.0 Ω |
| 0.1 mA | 0 to 250.00 Ω |
| 1 mA | 0 to 25.000 Ω |
| 10 mA | 0 to 2500.0 Ω |
| 100 mA | 0 to 250.00 Ω |
| 1 A | 0 to 25.000 Ω |
| 10 A | 0 to 2500.0 Ω |
| 1 A | 0 to 2500.0 Ω |
| 10 A | 0 to 250.00 Ω |
| Temperature Coefficient | < 0.01% per ºC, from 5 ºC to 40 ºC |
| Maximum Altitude | 2000m (6562 ft) to full safety specifications |
| Display size/type | Main 5 digit + 2 x 5 digit secondary displays |
| Battery type | 6 V, 7Ah sealed lead acid |
| Mains voltage input range | 90 - 264 V, 50-60 Hz |
| Charge time | 8 hours |
| Backlight | LED backlight |
| Battery life | 1000 Auto (3 sec) tests |
| Auto power down | 300s |
| Mode Selection | Rotary switch |
| Range selection | Rotary switch |
| Weight | 6.7 kg |
| Case dimensions | L315mm x W285mm x H181mm |
| Pouch for test leads | Yes (lid mounted) |
| Test leads | DH4 lead set included |
| IP rating | IP65 case closed, IP54 battery operation |
| Safety rating | In accordance with IEC61010-1, CATIII 300 V when used with DH7 leads |
| Operating temperature and humidity | +5ºC to +45ºC (41ºF to 113ºF) at full specification, -10°C to +50°C (14°F to 122°F) at reduced accuracy of ±0.5%, <90% RH |
| Storage temperature and humidity | -25°C to +60°C, <90%RH |
| EMC | In accordance with IEC61326-1 (Heavy industrial) |
| Noise rejection | Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level. |
| Maximum lead resistance | 100 mΩ total for 10 A operation irrespective of battery condition. |
- 1006-444 - DH4 Modular duplex handspike set 1.5m
- 1000-036 - Test lead pouch (lid mounted)
- 2000-869 - DLRO10HD User guide CD
- 6170-618 - Warranty book









Reviews
There are no reviews yet.