Thermo Scientific 2115204 – Orion Dual Star pH/ISE Dual Channel Benchtop Meter Nitrate and pH Kit

$2,354.00
In Stock

Industrial research hubs and centralized agricultural testing facilities maximize precise nitrate contamination tracking and secure strict regulatory compliance via the Thermo Scientific 2115204 Orion Dual Star benchtop meter kit. This comprehensive PH Meters testing suite provides a dual-parameter visual interface window, a specialized nitrate ion-selective electrode, and an advanced ROSS glass combination pH probe. The unit relies on built-in software filtering technology to preserve calibration alignment accuracy.

In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Thermo-Scientific-2115204
Category:
Brand:

Thermo Scientific 2115204 - Orion Dual Star pH/ISE Dual Channel Benchtop Meter Nitrate and pH Kit Specs

DescriptionOrion Dual Star pH/ISE dual channel benchtop meter nitrate & pH kit with Orion nitrate ion selective electrode, ROSS Sure-Flow glass-body pH electrode, ATC probe, solutions and stand
ModelOrion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter
IncludesDual Star pH/ISE dual channel meter, 9707BNWP Orion nitrate ion selective electrode, 8172BNWP ROSS Sure-Flow glass-body pH electrode, 927007MD Orion stainless steel ATC probe, 096019 Orion Star series stirrer probe, 930707 Orion 100 ppm nitrate standard (475 mL), 930711 Orion nitrate ISA ionic strength adjuster (475 mL), 810199 ROSS pH buffer and solution kit, electrode stand, computer interface cable, universal power supply, literature and meter test certificate
Range (pH)-2.000 to 19.999pH
Accuracy (pH)±0.002pH
Resolution (pH)0.1, 0.01, 0.001pH
Range (mV)±1999.9mV
Range (Relative mV)±1999.9mV
Range (ORP)±1999.9mV
Resolution (mV)0.1mV
Accuracy (mV)±0.2 mV or ±0.05% of reading whichever is greater
Range (ISE)0.0001 to 19900 with selectable units of ppm, Molar, mg/L, % or unit-less
Resolution (ISE)0.0001 minimum, 1 to 3 significant digits (user selectable)
Accuracy (ISE)±0.2 mV or ±0.05% of reading whichever is greater
Advanced ISE FunctionsSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition, single known subtraction, double known addition and double known subtraction
CalibrationpH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP and temperature
Calibration Points (pH)1 to 6
Calibration Points (ISE)2 to 6
Calibration Points1 point relative mV (RmV) mode, 1 point ORP mode
Isopotential Point7.000pH (adjustable), 1.000 ISE (adjustable)
Range (Temperature)-5.0° to 105.0°C, 22.0° to 221.0°F
Resolution (Temperature)0.1°C, 0.1°F
Accuracy (Temperature)±0.1°C
Temperature SelectionManual or automatic with ATC temperature probe
Temperature Probe Calibration1 point temperature offset calibration
Channels2
Backlight OptionYes, adjustable
Display TypeGraphic LCD with backlight
KeypadNumeric with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement ModespH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
StabilitySmart Stability and Smart Averaging
Data Management DetailsTransfer single, range or all data points to printer or computer
Log Function TypeAutomatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and Timed Reading measure modes; manual data logging with Continuous measure mode
Data Points1000 with date and time stamp
Alarm OutputHigh/low limit alarm
MemoryNon-volatile memory preserves data log, calibration log and meter settings
Methods10 per channel with password protection
InputsTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
OutputsUSB, RS232
LanguagesEnglish, Spanish, French, Italian and German
Probe TypepH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)
AC AdapterUniversal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Power SupplyUniversal AC adapter (included)
Electrical Requirements90 to 260VAC 50/60Hz
Temperature (English) Operating41° to 113°F (ambient)
Temperature (Metric) Operating5° to 45°C (ambient)
Relative Humidity Range5 to 85 %, non-condensing
Dimensions (L x W x H)24 x 17 x 9cm (9.5 x 6.7 x 3.5 in.)
Weight (English)2 lb.
Weight (Metric)0.9kg
Certifications/ComplianceCE, TUV 3-1, FCC Class A
Warranty3 year meter warranty
Unit SizeEach
  • Dual Star pH/ISE dual channel meter
  • 9707BNWP - Orion nitrate ion selective electrode
  • 8172BNWP - ROSS Sure-Flow glass-body pH electrode
  • 927007MD - Orion stainless steel ATC probe
  • 096019 - Orion Star series stirrer probe
  • 930707 - Orion 100 ppm nitrate standard (475 mL)
  • 930711 - Orion nitrate ISA ionic strength adjuster (475 mL)
  • 810199 - ROSS pH buffer and solution kit
  • Electrode stand
  • Computer interface cable
  • Universal power supply
  • Literature and meter test certificate

Reviews

There are no reviews yet.

Be the first to review “Thermo Scientific 2115204 – Orion Dual Star pH/ISE Dual Channel Benchtop Meter Nitrate and pH Kit”

Your email address will not be published. Required fields are marked *