Hioki PW3360-21/500Pro KIT – 500 A Power Demand Analyzer Kit

$2,272.00
In Stock
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Hioki-PW3360-21-500Pro-KIT
Category:
Brand:

Hioki PW3360-21/500Pro KIT - 500 A Power Demand Analyzer Kit Specs

TypeClamp On Power Logger
Measurement line typeSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Measurement line Frequency50/ 60 Hz
Number of input channelsVoltage: 3 channels U1 to U3   Current: 3 channels I1 to I3
Voltage range600 V AC   Total display area: 5V to 1000 V (less than 5 V displays as 0 V)   When RMS voltage is zero, zero is displayed for all orders of harmonic voltage.   Effective measurement range: 90 V to 780 V, peak: ±1400V   [OVER] indicates over-range warning
Current rangesLoad current   CLAMP ON SENSOR 9694 : 500m/1/5/10/50 A   CLAMP ON SENSOR 9695-02 : 500m/1/5/10/50 A   CLAMP ON SENSOR 9660 : 5/10/50/100 A   CLAMP ON SENSOR 9695-03 : 5/10/50/100 A   CLAMP ON SENSOR 9661 : 5/10/50/100/500 A   CLAMP ON SENSOR 9669 : 100/200/1k A   FLEXIBLE CLAMP ON SENSOR CT9667 : 500/5k A      Leakage current   LEAK CLAMP ON SENSOR 9657-10 : 50m/100m/500m/1/5 A   LEAK CLAMP ON SENSOR 9675 : 50m/100m/500m/1/5 A   Total display range: Within 0.4 to 130% of the range   (zero is suppressed for less than 0.4%)      When RMS current is zero, zero is displayed for all orders of harmonic current.   Effective measurement range: Within 5 to 110% of the range   peak: ±400% of range, however, maximum range is 200%.   [OVER] indicates over-range warning
Power ranges300.00 W to 9.0000 MW   Depends on voltage/current combination and measured line type   Total display range: Within 0 to 130% of the range   (“0W” display indicates zero rms voltage and/or current)   When RMS voltage and current are zero, zero is displayed for all orders of harmonic active power and harmonic reactive power.   Effective measurement area: Within 5 to 110% of the range
VT ratio settingsAny (0.01 to 9999.99)   Selections (1/60/100/200/300/600/700/1000/2000/2500/5000)
CT ratio settingsAny (0.01 to 9999.99)   Selections (1/40/60/80/120/160/200/240/300/400/600/800/1200)
Input methodsVoltage: Insolated inputs (except between U1, U2, U3 and N)   Current: Isolated input using a clamp-on sensor
Input resistanceVoltage input part: 3 MΩ ±20% (50/ 60 Hz)
Maximum rated voltage between terminalsVoltage input section: 1000 VAC, 1400 Vpeak   Current input section: 1.7 VAC, 2.4 Vpeak
Maximum rated voltage to earthVoltage input section: 600V Measurement Category III   300V Measurement Category IV   Current input section: Depends on clamp sensor in use.
StandardIEC61000-4-7:2002 compliant, but without interharmonics
Window width10 cycles at 50 Hz, and 12 cycles at 60 Hz (with interpolation)
Points per windowRectangular, 2048 points
Analysis ordersUp to the 40th order
THD calculation selectionTHD-F/THD-R
Analysis itemsHarmonic level: Voltage, current and power levels for each harmonic(U12 and I12 obtained by calculation of the third channel in 3P3W2M wiring are not displayed. Phase voltage is used for 3P3W3M wiring.)      Harmonic content: Voltage, current and power contents for each harmonic.   Harmonic  phase  angle:  Voltage,  current  and  power  phase  angles  for  each  harmonic.   Total harmonic distortion factor: Voltage and current (THD-F or THD-R)
Measurement accuracyHarmonic level   1st to 15th orders: ±5% rdg. ±0.2% f.s.   16th to 20th orders: ±10% rdg. ±0.2% f.s.   21st to 40th orders: ±20% rdg. ±0.3% f.s.      For voltage and current, add accuracy of clamp sensor.      Harmonic power phase angle   1st to 3rd orders: ±3°+clamp sensor accuracy   4th to 40th orders: ±0.1°×k±3°+clamp sensor accuracy   For each harmonic order at 6 V, harmonic current level is regulated at 1% f.s.      Total harmonic distortion factor: Accuracy unspecified
Display device3.5 inch TFT color LCD (320 × 240 pixel)      Japanese, English, Chinese, Korean, German, Italian, French, Spanish, TurkishBacklight auto-off function (after 2 minutes)When AUTO OFF is active, the Power LED blin
Operating environmentIndoors, Pollution degree 2, altitude up to 2000 m (6562-ft.)
Operating temperature and humidity(no condensation)-10°C to 50°C (14°F to 122°F), 80% RH or less   During LAN communication: 0°C to 50°C (32°F to 122°F), 80% RH or less   During battery operation: 0°C to 40°C (32°F to 104°F), 80% RH or less   During battery charging: 10°C to 40°C (50°F to 104°F), 80% RH or less
Storage temperature and humidity(no condensation)-20°C to 60°C (-4°F to 140°F), 80% RH or less   However, the batteryُs storage temperature range is -20°C to 30°C (-4°F to 86°F), 80% RH or less
Dielectric strength4.29 kVrms AC (1 mA sense current) between voltage input ter-minals and external terminals, 50/ 60 Hz for 60 sec.
Applicable standardsSafety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3
Charge functionCharges the battery regardless of whether the instrument is on or off.   Charge time: Max. 6 hr. 10 min. (reference value at 23°C)
Maximum rated powerWhen the Z1006 AC Adapter is used: 40 VA (including AC adapter),  13 VA (PW3360-20 instrument only)   When the 9459 Battery Pack is used: 3 VA
Continuous battery operation timeApprox. 8 hr. (Continuous, backlight off)(when using the battery pack)
Backup battery lifeClock and settings (Lithium battery), Approx. 10 years @23°C (@73.4°F)
DimensionsApprox. 180W(7.09") × 100H(3.94") × 48D (1.89") mm (without PW9002)   Approx. 180W(7.09") × 100H(3.94") × 68D (2.68") mm (with PW9002)
MassApprox. 550g (19.4 oz) (without PW9002), Approx. 830g (29.3 oz) (with PW9002)
     
  • PW3360-21 - Clamp On Power Logger
  •  
  • (3X) 9661 - Clamp On Sensor
  •  
  • SF1001 - Power Logger Viewer
  •  
  • Z4001 - SD Memory Card 2GB
  •  
  • PW9002 - Battery Set
  •  
  • PW3360 Hard Case

Reviews

There are no reviews yet.

Be the first to review “Hioki PW3360-21/500Pro KIT – 500 A Power Demand Analyzer Kit”