| 729 30G | Psi range, resolution |
| Bar range, resolution | -0.82737 to 2.06842 bar |
| kPa range, resolution | -82.737 to 206.843 kPa |
| Comment | No wireless communication |
| 729 150G | Psi range, resolution |
| Bar range, resolution | -0.8273 to 10.3421 bar |
| kPa range, resolution | -82.73 to 1034.21 kPa |
| Comment | No wireless communication |
| 729 300G | Psi range, resolution |
| Bar range, resolution | -0.8273 to 20.6843 bar |
| kPa range, resolution | -82.73 to 2068.43 kPa |
| Comment | No wireless communication |
| 729 30G FC | Psi range, resolution |
| Bar range, resolution | -0.82737 to 2.06842 bar |
| kPa range, resolution | -82.737 to 206.843 kPa |
| Comment | Wireless communication for Fluke Connect |
| 729 150G FC | Psi range, resolution |
| Bar range, resolution | -0.8273 to 10.3421 bar |
| kPa range, resolution | -82.73 to 1034.21 kPa |
| Comment | Wireless communication for Fluke Connect |
| 729 300G FC | Psi range, resolution |
| Bar range, resolution | -0.8273 to 20.6843 bar |
| kPa range, resolution | -82.73 to 2068.43 kPa |
| Comment | Wireless communication for Fluke Connect |
| 729CN 200K | Psi range, resolution |
| Bar range, resolution | -0.82737 to 2.06842 bar |
| kPa range, resolution | -82.737 to 206.843 kPa |
| Comment | For China, no wireless communication |
| 729CN 1M | Psi range, resolution |
| Bar range, resolution | -0.8273 to 10.3421 bar |
| kPa range, resolution | -82.73 to 1034.21 kPa |
| Comment | For China, no wireless communication |
| 729CN 2M | Psi range, resolution |
| Bar range, resolution | -0.8273 to 20.6843 bar |
| kPa range, resolution | -82.73 to 2068.43 kPa |
| Comment | For China, no wireless communication |
| 729CN 200K FC | Psi range, resolution |
| Bar range, resolution | -0.82737 to 2.06842 bar |
| kPa range, resolution | -82.737 to 206.843 kPa |
| Comment | For China, wireless communication for Fluke Connect |
| 729CN 1M FC | Psi range, resolution |
| Bar range, resolution | -0.8273 to 10.3421 bar |
| kPa range, resolution | -82.73 to 1034.21 kPa |
| Comment | For China, wireless communication for Fluke Connect |
| 729CN 2M FC | Psi range, resolution |
| Bar range, resolution | -0.8273 to 20.6843 bar |
| kPa range, resolution | -82.73 to 2068.43 kPa |
| Comment | For China, wireless communication for Fluke Connect |
| 729JP 200K | kPa range, resolution |
| Comment | For Japan, no wireless communication |
| 729JP 1M | kPa range, resolution |
| Comment | For Japan, 1 MPa range, no wireless communication |
| 729JP 2M | kPa range, resolution |
| Comment | For Japan, 2 MPa range, no wireless communication |
| 729JP 200K FC | kPa range, resolution |
| Comment | For Japan, wireless communication for Fluke Connect |
| 729JP 1M FC | kPa range, resolution |
| Comment | For Japan, wireless communication for Fluke Connect |
| 729JP 2M FC | kPa range, resolution |
| Comment | For Japan, wireless communication for Fluke Connect |
| mA measure, source and simulate | 0 mA to 24 mA |
| Volts dc measure | 0 V dc to 30 V dc |
| mA dc source, simulate and measure | 1 μA |
| Voltage dc measurement | 1 mV |
| Accuracy | 0.01% ±2 LSD all ranges (at 23 °C ±5 °C) |
| Stability | 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C |
| mA simulate external voltage requirement | 12 V dc to 30 V dc |
| Loop compliance voltage | 24 V dc @ 20 mA |
| mA simulate external voltage requirement | 12 V dc to 30 V dc |
| Temperature measurement only/100 Ω Pt(385) RTD | -50 °C to 150 °C (-58 °F to 302 °F) |
| Temperature resolution | 0.01 °C (0.01 °F) |
| Temperature accuracy | ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory) |
| Drive capability | 1200 Ω without HART resistor, 950 Ω with internal HART resistor |
| Size (HxWxL) | 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in) |
| Weight | 6.5 lbs., 2.95 kg |
| Ingress protection | IP54 |
| Operating temperature | -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control |
| Operating temperature with battery | -10 °C to 40 °C |
| Storage temperature | -40 °C to 60 °C |
| Operating altitude | 3000 m |
| Storage altitude | 13000 m |
| Radio frequency certification | FCC ID: T68-FBLE IC:6627A-FBLE |
| Wireless radio frequency range | 2412 MHz to 2462 MHz |
- Calibrator without wireless communication
- Soft case
- Stackable test leads
- AC280 hook clips
- Alligator clips
- Test probes
- Magnetic hanger kit
- Carrying strap
- Quick start guide
- Safety sheet
- Power supply
- Rechargeable battery (installed)
- Hose kit with push fit adapters
- Hanging clip
- USB cable
- 1/8 in FNPT to 1/4 in FNPT adapter
- 1/8 in FNPT to F-M20 adapter
- 1/8 in FNPT to 1/4 in FBSP adapter
- PTFE tape
- (2) sintered filters
- Water trap drain and valve tuning hoses.
- Calibration Certificate with data
- Traceable to the International System of units (SI)
- including NIST