Autonics MP5W-41 – High Performance Digital Pulse Meter, Relay triple (H, GO, L), 100-240 VAC

$159.00
In Stock
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Autonics-MP5W-41
Category:
Brand:

Autonics MP5W-41 - High Performance Digital Pulse Meter, Relay triple (H, GO, L), 100-240 VAC Specs

SeriesMP5S
Display method7 Segment LED(Zero Blanking method)
Character sizeW4×H8mm
Display range-19999 to 99999
PowerAC Voltage
AC/DC Voltage24VAC 50/60Hz, 24-48VDC
Power ConsumptionAC Voltage
AC/DC VoltageMax. 6.0VA (24VAC 50/60Hz), Max. 4.5W (24-48VDC)
Permissible voltage range90 to 110% of rated voltage
External sensor power12VDC±10%, 80mA
Sub power supply-
Input frequencySolid state input: max. 50kHz (pulse width: min. 10µs)   Contact input: max. 45Hz (pulse width: min. 11ms)
Input method[Voltage input] High: 4.5-24VDC, Low: 0-1.0VDC, Input impedance: 2.4kΩ   [No-voltage input] Short-circuit impedance: max. 80Ω, Residual voltage: min. 1V, Open-circuit impedance: min. 100kΩ
Measurement rangeMode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz   Mode F3, F4, F5, F6 : 0.01 to max. of each time range   Mode F11, F12, F13, F16 : 0 to 99999   Mode F14, F15 : -19999 to 99999
Measurement accuracy(23±5°C)Mode F1, F2, F7, F8, F9, F10: F.S.±0.05%rdg±1digit   Mode F3, F4, F5, F6: F.S.±0.01%rdg±1digit
Display cycleOFF (for F2, F16), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
Operation modeFrequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10), Length measurement 1 (F11), Interval (F12), Accumulation (F13), Addition/Subtraction-individual input (F14), Addition/Subtraction-phase difference input (F15), Length measurement 2 (F16)
Pre-scale functionDirect input method (0.0001×10-9 to  9.9999×109)
Hysteresis0 to 9999*1
OutputMain
Relay(Quintuple)-
NPN/PNP open   collector quintupleMax. 30VDC 30mA
SubBCD Dynamic
AnalogDC4-20mA/DC0-20mA max. load 500Ω
CommunicationRS485 communication output (Modbus RTU method)
Memory retentionNon-volatile memory (number of inputs: 100,000 operations)
Insulation resistanceMin. 100M? (at 500VDC megger)
Dielectric strength2,000VAC 60Hz for 1min.
Noise resistance±2kV the square wave noise (pulse width: 1µs) by the noise simulator
VibrationMechanical
Malfunction0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 minutes
ShockMechanical
Malfunction100m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Relay Life cycleMechanical
Electrical-
EnvironmentAmbient Temp.
Ambient Humi.35 to 85%RH, storage: 35 to 85%RH
WeightApprox. 191g (approx. 132g)

Reviews

There are no reviews yet.

Be the first to review “Autonics MP5W-41 – High Performance Digital Pulse Meter, Relay triple (H, GO, L), 100-240 VAC”

Your email address will not be published. Required fields are marked *