Autonics MP5W-41 – High Performance Digital Pulse Meter, Relay triple (H, GO, L), 100-240 VAC
$159.00
In Stock
In Stock
Autonics MP5W-41 - High Performance Digital Pulse Meter, Relay triple (H, GO, L), 100-240 VAC Specs
| Series | MP5S |
| Display method | 7 Segment LED(Zero Blanking method) |
| Character size | W4×H8mm |
| Display range | -19999 to 99999 |
| Power | AC Voltage |
| AC/DC Voltage | 24VAC 50/60Hz, 24-48VDC |
| Power Consumption | AC Voltage |
| AC/DC Voltage | Max. 6.0VA (24VAC 50/60Hz), Max. 4.5W (24-48VDC) |
| Permissible voltage range | 90 to 110% of rated voltage |
| External sensor power | 12VDC±10%, 80mA |
| Sub power supply | - |
| Input frequency | Solid state input: max. 50kHz (pulse width: min. 10µs) Contact input: max. 45Hz (pulse width: min. 11ms) |
| Input method | [Voltage input] High: 4.5-24VDC, Low: 0-1.0VDC, Input impedance: 2.4kΩ [No-voltage input] Short-circuit impedance: max. 80Ω, Residual voltage: min. 1V, Open-circuit impedance: min. 100kΩ |
| Measurement range | Mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz Mode F3, F4, F5, F6 : 0.01 to max. of each time range Mode F11, F12, F13, F16 : 0 to 99999 Mode F14, F15 : -19999 to 99999 |
| Measurement accuracy(23±5°C) | Mode F1, F2, F7, F8, F9, F10: F.S.±0.05%rdg±1digit Mode F3, F4, F5, F6: F.S.±0.01%rdg±1digit |
| Display cycle | OFF (for F2, F16), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle) |
| Operation mode | Frequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10), Length measurement 1 (F11), Interval (F12), Accumulation (F13), Addition/Subtraction-individual input (F14), Addition/Subtraction-phase difference input (F15), Length measurement 2 (F16) |
| Pre-scale function | Direct input method (0.0001×10-9 to 9.9999×109) |
| Hysteresis | 0 to 9999*1 |
| Output | Main |
| Relay(Quintuple) | - |
| NPN/PNP open collector quintuple | Max. 30VDC 30mA |
| Sub | BCD Dynamic |
| Analog | DC4-20mA/DC0-20mA max. load 500Ω |
| Communication | RS485 communication output (Modbus RTU method) |
| Memory retention | Non-volatile memory (number of inputs: 100,000 operations) |
| Insulation resistance | Min. 100M? (at 500VDC megger) |
| Dielectric strength | 2,000VAC 60Hz for 1min. |
| Noise resistance | ±2kV the square wave noise (pulse width: 1µs) by the noise simulator |
| Vibration | Mechanical |
| Malfunction | 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 minutes |
| Shock | Mechanical |
| Malfunction | 100m/s² (approx. 30G) in each X, Y, Z direction for 3 times |
| Relay Life cycle | Mechanical |
| Electrical | - |
| Environment | Ambient Temp. |
| Ambient Humi. | 35 to 85%RH, storage: 35 to 85%RH |
| Weight | Approx. 191g (approx. 132g) |