Adash America A4404 DDS Vibration Meter
In Stock
Adash America A4404 DDS Vibration Meter Specs
| Input channels | 4 AC, ICP® power supply on/off 4 DC for process values 1 TACHO for external trigger |
| Input range | AC +/- 12 V peak-peak DC +/- 24V |
| AD conversion | 24 bit, 64 bit internal signal processing No AutoGain function! |
| Dynamic range S/N | 120 dB |
| Frequency ranges | Maximum range: 1 Hz - 90 kHz (1 Ch, 194 kHz sampling) Maximum range: 1 Hz - 25 kHz (4 Ch, 64 kHz sampling) Minimum range: 1 Hz - 25 Hz (4 Ch, 64 Hz sampling) |
| Sampling mode | Fully simultaneous for 4 channels |
| FFT resolution | Min. 100 lines Max. 3 276 800 lines |
| Unit modes | Analyzer - analytic measurement Data collector - route measurement Balancer - on-site balancing Recorder - signal recording Stethoscope FASIT - Expert system for fault detection Octave analyzer Bump test ADS - Animated Deflection Shapes |
| Processor | According to the PC |
| Memory, Route | According to the PC hard drive |
| Data processing | Real time FFT DEMOD - ENVELOPE analysis ACMT - low speed bearing analysis Order analysis User band pass analysis RPM measurement DC measurement Orbit measurement |
| Signal Recorder | 64 kHz sampling frequency 4 Ch memory consumption 3 GB/hour 4 Ch total recording - 35 hours |
| Trigger | Manual, External, Signal level, Time Use for signal recording trigger Speed change, Time interval |
| Communication | USB |
| Temperature range | -10˚C to +50˚C |
| Power | USB powered |
| Case | Aluminium heavy duty |
| Size and Weight | 110 x 115 x 35 mm, 350 g |







Reviews
There are no reviews yet.