Associated Research 08204 – OMNIA II Multi-Function Safety Compliance Analyzer
$8,059.00
In Stock
In Stock
Associated Research 08204 - OMNIA II Multi-Function Safety Compliance Analyzer Specs
| PLC Remote Control | Input: Test, Reset, Interlock, Recall File 1 through 3 Output: Pass, Fail, Test-in-Process |
| Safety | Built-in SmartGFI circuit |
| Memory | 10,000 Steps |
| Interface | Standard: USB/RS-232 Optional: Ethernet or GPIB |
| Security | Advanced security system with access levels and username/password requirements |
| Dimensions (W x H x D) | 16.93" x 5.24" x 19.69" (430 x 133 x 500 mm) |
| Voltage | 115/230 V Auto Range, ± 15 % Variation |
| Frequency | 50/60 Hz ± 5% |
| Fuse | 115 VAC, 230 VAC – 10 A Slow Blow 250 VAC |
| Output Rating | 5 kV @ 50 mAAC 5 kV @ 100 mAAC (Models 825X) 6 kV @ 20 mADC |
| Voltage Setting | Resolution: Accuracy: |
| HI and LO-Limit | AC Total |
| Range: Resolution: | 10.00 – 50.00 mA (100.00 mA, models 825X) 0.01 mA |
| Range: Resolution: | ± (2% of setting + 2 counts) |
| AC Real | Range: Resolution: |
| Range: Resolution: | 10.00 – 50.00 mA (100.00 mA, models 825X) 0.01 mA |
| Accuracy | ± (3% of setting + 50 μA) |
| DC | Range: Resolution: |
| Range: Resolution: | 1,000 – 20,000 μA 1 μA |
| Accuracy | ± (2% of setting + 2 counts |
| Arc Detection | Range: |
| Ground Continuity | Current: DC 0.1 A ± 0.01 A, fi xed Max. Ground Resistance: 1 Ω ± 0.1 Ω, fi xed |
| Ground Fault Interrupt | GFI Trip Current: 0.4 mA – 5.0 mA (AC or DC) HV Shut Down Speed: < 1 ms |
| DC Output Ripple | ≤ 4% Ripple rms at 5 kVDC at 20 mA Resistive Load |
| Discharge Time | ≤ 50 ms No Load, < 100 ms for Capacitive Load |
| Max Capacitive Load, DC Mode | 1 μF < 1 kV 0.75 μF < 2 kV 0.5 μF < 3 kV |
| AC Output Waveform | Sine Wave, Crest Factor = 1.3 – 1.5 |
| Output Frequency | Range: |
| Output Regulation | ± (1% of output + 5 V) from no load to full load and over input voltage range |
| Dwell Timer | Range: Range: |
| Ramp Timer | Ramp-up: Ramp-Down: |
| Voltage Setting | Range: |
| HI and LO-Limit | Range: Resolution: |
| Range: Resolution: | 100.0 MΩ – 999.9 MΩ 0.1 MΩ |
| Range: Resolution: | 1,000 MΩ – 50,000 MΩ 1 MΩ (HI-Limit: 0=OFF) |
| Ramp Timer | Ramp-up: Ramp-Down: |
| Delay Timer | Range: |
| Output Voltage (Open Circuit Limit) | Range: |
| Output Frequency | Range: |
| Output Current | Range: Resolution: Accuracy: |
| Maximum Loading | 1.00 – 10.00 A, 0 – 600 mΩ 10.01 – 30.00 A, 0 – 200 mΩ 30.01 – 40.00 A, 0 – 150 mΩ |
| HI and LO-Limit | Range: Resolution: Accuracy: |
| Range: Resolution: Accuracy: | 0 – 600 mΩ for 1.00 – 5.99 A 1 mΩ ± (3% of reading + 3 mΩ) |
| Dwell Timer | Range: |
| Milliohm Offset | Range: |
| Output Current | DC 0.01 A ± 0.00001 A |
| Resistance Display | Range: |
| HI and LO-Limit | Range: Resolution: |
| Range 2: Resolution: | 10.1 – 100.0 Ω 0.1 Ω |
| Range 3: Resolution: Accuracy: | 101 – 1,000 Ω 1 Ω ± (1% of reading + 3 counts) |
| Range 4: Resolution: Accuracy: | 1,001 – 10,000 Ω 1 Ω ± (1% of reading + 10 counts) (Max Limit: 0=OFF) |
| Dwell Timer | Range: |
| Milliohm Offset | Range: |
| DUT Power | Voltage: Current: Range: Resolution: Accuracy |
| Delay Time Setting | Range: |
| Dwell Time Setting | Range: |
| Trip Point Settings & Metering | Voltage |
| Volt-Hi Volt-LO | Range: Resolution: Accuracy: |
| Amp-HI Amp-LO | Range: Resolution: Accuracy: |
| Power-HI Power-LO | Range: Resolution: Accuracy: |
| PF-HI PF-LO | Range: Resolution: Accuracy: |
| Leak-HI Leak-LO | Range: Resolution: Accuracy: |
| Timer Display | Range: Resolution: Accuracy: |
| Dut Power | Voltage: Current: |
| Voltage Display | Range: Resolution: Accuracy: |
| Short Circuit Protection: | 23 AAC, Response Time < 3 s |
| Reverse Power Switch | Reverse polarity switch setting select ON/OFF/AUTO ON: Reverse power OFF: Normal AUTO: Automatic Reverse Polarity |
| Neutral Switch | ON/OFF selection for single fault condition |
| Ground Switch | ON/OFF selection for Class I single fault condition |
| Probe Setting | Surface to Surface (PH – PL) Surface to Line (PH – L) Ground to Line (G – L) |
| Touch Current High Limit (rms) | Range: Resolution: |
| Touch Current Display (rms) | Range 1: |
| Range 2: | 28.0 μA ~ 130.0 μA, frequency DC, 15 Hz – 1 MHz |
| Range 3: | 120.0 μA ~ 550.0 μA, frequency DC, 15 Hz – 1 MHz |
| Resolution for Ranges 1, 2, 3: | 0.1 μA |
| Accuracy for Ranges 1, 2, 3: | DC: 15 Hz < f <100 KHz: ± (2% of reading + 3 counts) 100 KHz < f < 1 MHZ: ± 5% of reading (10.0 μA – 999.9 μA) |
| Range 4: | 400 μA ~ 2100 μA, frequency DC, 15 Hz – 1 MHz |
| Range 5: | 800 μA ~ 8500 μA, frequency DC, 15 Hz – 1 MHz |
| Resolution for Ranges 4 & 5: | 1 μA |
| Accuracy for Ranges 4 & 5: | DC: 15 Hz < f <100 KHz: ± (2% of reading + 3 counts) 100 KHz < f < 1 MHZ: ± 5% of reading (10 μA – 8500 μA) |
| Range 6: | 8.00 mA ~ 10.00 mA, frequency DC 15 Hz – 100 kHz |
| Resolution: | 0.01 mA |
| Accuracy | DC: 15 Hz < f < 100 KHz: ± 5% of reading (0.01 mA -10.00 mA) |
| Touch Current Display (Peak) | Range 1: |
| Range 2: | 28.0 μA ~ 130.0 μA, frequency DC – 1 MHz |
| Range 3: | 120.0 μA ~ 550.0 μA, frequency DC – 1 MHz |
| Resolution for Ranges 1, 2, 3: | 0.1 μA |
| Accuracy for Ranges 1, 2, 3: | DC: ± (2% of reading + 2 μA) 15 Hz < f < 1 MHZ : ± 10% of reading + 2 μA |
| Range 4: | 400 μA ~ 2100 μA, frequency DC – 1 MHz |
| Range 5: | 1800 A ~ 8500 μA, frequency DC – 1 MHz |
| Resolution for Ranges 4 & 5: | 1 μA |
| Accuracy for Ranges 4 & 5: | DC: ± (2% of reading + 2 μA) 15 Hz < f < 1 MHz: ±(10% of reading + 2 μA) |
| Range 6: | 8.0 mA ~10.00 mA, frequency DC – 100 KHz |
| Resolution: | 0.01 mA |
| Accuracy | DC: ± (2% of reading + 3 counts) 15 Hz < f < 100 KHz: ± (10% of reading + 2 counts) |
| MD Circuit Module | MD1: UL544NP, UL484 , UL923, UL471, UL867, UL697 MD2: UL544P MD3: IEC 60601-1 MD4: UL1563 MD5: IEC60990 Fig4 U2, IEC 60950-1, IEC60335-1, IEC60598-1, IEC60065, IEC61010 MD6: IEC60990 Fig5 U3, IEC60598-1 MD7: IEC60950, IEC61010-1 FigA.2 (2K ohm) for Run function MD8: IEC60990/60950 Fig4 U1 |
| External MD | Basic measuring element 1 kΩ |
| Scope Output Interface | BNC type connector on rear panel for Oscilloscope connection |
- High Voltage Cable
- High Current Output Cable
- High Current Return Cable
- High Current Test Lead
- Fuse
- USB Cable AB-Type 1.8m
- Line Cord
- Adapter Box
- (2) Bracket Rack Mount 3U
- (2) Handle Rack Mount 3U
- (4) Screw M4 x 12mm FHMS
- NIST Traceable Calibration Certificate





Reviews
There are no reviews yet.