Fluke 1663 SCH Installation Tester with RCD Type B (SCHUKO)
$1,465.00
In Stock
In Stock
Fluke 1663 SCH Installation Tester with RCD Type B (SCHUKO) Specs
| Model | 1662 |
| Insulation-PreTest ™ safety function NEW | • |
| Insulation at L-N, L-PE, N-PE inputs NEW | • |
| Auto Test sequence NEW | • |
| Loop and line resistance—mΩresolution | • |
| Continuity at L-N, L-PE, N-PE inputs NEW | • |
| Test smooth dc sensitive RCDs (Type B/B+) | • |
| Earth resistance | • |
| Voltage trms (ac and dc) and frequency | • |
| Wiring polarity checker, detects broken PE and N wires | • |
| Insulation resistance | • |
| Continuity and resistance | • |
| Measure motor windings with continuity test (@ 10 mA) | • |
| Loop and line resistance | • |
| Prospective Earth Fault Current (PEFC/IK) | • |
| Prospective Short-Circuit Current (PSC/IK) | • |
| RCD trip time | • |
| RCD trip current (ramp test) | • |
| Measures trip time and current for RCD type A and AC in one test | • |
| RCD variable test current | • |
| Automatic RCD test sequence | • |
| Phase sequence test | • |
| Fluke Connect ® compatibility NEW | • |
| ShareLive ™ calling NEW | • |
| Fluke Cloud ™ storage NEW | • |
| On/Off switchable Auto Start for RCD and Looptest NEW | • |
| Self-test | • |
| Illuminated display | • |
| Z Max memory NEW | • |
| Memory | • |
| IR-USB and BLE interface (use with optional Fluke DMS software and FVF) | IR-USB |
| Heavy duty mains cord with single input connector NEW | • |
| Hard case | • |
| Remote control probe | • |
| Zero adapter | • |
| Specification | Characteristic |
| Size | 10 cm (L) x 25 cm (W) x 12.5 cm (H) |
| Weight (incl. batteries) | approx. 1.3 kg |
| Battery size, quantity | 1.5 V type AA (IEC LR6), 6 pcs. |
| Sealing | IP 40 |
| Safety | Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and CAN/CSA c22.2 No. 1010 |
| Overvoltage | CAT III 500 V, CAT IV 300 V |
| Performance | EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10 |
| Range | Resolution |
| 500 V | 0.1 V |
| Range (Autoranging) | Resolution |
| 20 Ω/200 Ω/2000 Ω | 0.01 Ω/0.1 Ω/1 Ω |
| 1662 | 1663/1664 FC |
| 100-250-500-1000 V | 50-100-250-500-1000 V |
| Test Voltage | Insulation Resistance Range |
| 50 V | 20 MΩ/50 MΩ |
| 100 V | 20 MΩ/100 MΩ |
| 250 V | 20 MΩ/200 MΩ |
| 500 V | 20 MΩ/200 MΩ/500 MΩ |
| 1000 V | 20 MΩ/200 MΩ/1000 MΩ |
| Insulation safety pretest | Requires to connect the Tester to L, N and PE. |
| Range | Resolution |
| 10 Ω(Hi current mΩmode)/20 Ω/200 Ω/2000 Ω | 1 mΩ/ 0.01 Ω/ 0.1 Ω/1Ω |
| Range | Resolution |
| 1000 A/10 kA (50 kA) | 1 A/0.1 kA |
| RCD Type | Model 1662 |
| AC1 | G2, S3 |
| Current Settings1 | Multiplier |
| RCD Type G | RCD Type S |
| 10-30-100-300-500-1000 mA – VAR | x ½, x 1 |
| 10-30-100 mA | x 5 |
| Current Range | Step Size |
| Type G | Type S |
| 30 % to 110 % of RCD rated current1 | 10 % of I ▵N 2 |
| Notes 30 % to 210 % for Type A I▵N = 10mA 20 % to 210 % for Type B | Specified trip current ranges (EN 61008-1): 50 % to 100 % for Type AC 35 % to 140 % for Type A (>10 mA) 35 % to 200 % for Type A (=10 mA) 50 % to 200 % for Type B |
| Range | Resolution |
| 200 Ω/2000 Ω | 0.1 Ω/1Ω |
| Icon | Range |
| Phase Sequence indicator is active | 100 to 500 V |
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead
- User's manual on CD-ROM