Fluke 1663 Multifunction Installation Tester with RCD TYPE B

$1,536.00
In Stock
In Stock
Commercial Pricing
Request for Quotations for Bulk Orders
SKU: Fluke-1663
Brand:

Fluke 1663 Multifunction Installation Tester with RCD TYPE B Specs

Model1662
Insulation-PreTest ™ safety function NEW
Insulation at L-N, L-PE, N-PE inputs NEW
Auto Test sequence NEW
Loop and line resistance—mΩresolution
Continuity at L-N, L-PE, N-PE inputs NEW
Test smooth dc sensitive RCDs (Type B/B+)
Earth resistance
Voltage trms (ac and dc) and frequency
Wiring polarity checker, detects broken PE and N wires
Insulation resistance
Continuity and resistance
Measure motor windings with continuity test (@ 10 mA)
Loop and line resistance
Prospective Earth Fault Current (PEFC/IK)
Prospective Short-Circuit Current (PSC/IK)
RCD trip time
RCD trip current (ramp test)
Measures trip time and current for RCD type A and AC in one test
RCD variable test current
Automatic RCD test sequence
Phase sequence test
Fluke Connect ® compatibility NEW
ShareLive ™ calling NEW
Fluke Cloud ™ storage NEW
On/Off switchable Auto Start for RCD and Looptest NEW
Self-test
Illuminated display
Z Max memory NEW
Memory
IR-USB and BLE interface (use with optional Fluke DMS software and FVF)IR-USB
Heavy duty mains cord with single input connector NEW
Hard case
Remote control probe
Zero adapter
SpecificationCharacteristic
Size10 cm (L) x 25 cm (W) x 12.5 cm (H)
Weight (incl. batteries)approx. 1.3 kg
Battery size, quantity1.5 V type AA (IEC LR6), 6 pcs.
SealingIP 40
SafetyComplies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and   CAN/CSA c22.2 No. 1010
OvervoltageCAT III 500 V, CAT IV 300 V
PerformanceEC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10
RangeResolution
500 V0.1 V
Range (Autoranging)Resolution
20 Ω/200 Ω/2000 Ω0.01 Ω/0.1 Ω/1 Ω
16621663/1664 FC
100-250-500-1000 V50-100-250-500-1000 V
Test VoltageInsulation Resistance Range
50 V20 MΩ/50 MΩ
100 V20 MΩ/100 MΩ
250 V20 MΩ/200 MΩ
500 V20 MΩ/200 MΩ/500 MΩ
1000 V20 MΩ/200 MΩ/1000 MΩ
Insulation safety pretestRequires to connect the Tester to L, N and PE.
RangeResolution
10 Ω(Hi current mΩmode)/20 Ω/200 Ω/2000 Ω1 mΩ/ 0.01 Ω/ 0.1 Ω/1Ω
RangeResolution
1000 A/10 kA (50 kA)1 A/0.1 kA
RCD TypeModel 1662
AC1G2, S3
Current Settings1Multiplier
RCD Type GRCD Type S
10-30-100-300-500-1000 mA – VARx ½, x 1
10-30-100 mAx 5
Current RangeStep Size
Type GType S
30 % to 110 % of RCD rated current110 % of I ▵N 2
Notes   30 % to 210 % for Type A I▵N = 10mA   20 % to 210 % for Type BSpecified trip current ranges (EN 61008-1):   50 % to 100 % for Type AC   35 % to 140 % for Type A (>10 mA)   35 % to 200 % for Type A (=10 mA)   50 % to 200 % for Type B
RangeResolution
200 Ω/2000 Ω0.1 Ω/1Ω
IconRange
Phase Sequence indicator is active100 to 500 V
     
  • 6x AA (IEC LR6) cell batteries
  •  
  • C1600 hard carrying case
  •  
  • Zero adapter
  •  
  • Heavy duty mains cord
  •  
  • STD standard test lead set
  •  
  • Padded carrying and waist strap
  •  
  • Quick reference guide
  •  
  • TP165X remote control probe and lead
  •  
  • User's manual on CD-ROM

Reviews

There are no reviews yet.

Be the first to review “Fluke 1663 Multifunction Installation Tester with RCD TYPE B”

Your email address will not be published. Required fields are marked *