Compliance HT-2000P V2 – Hipot Tester, 0-2000 VAC @ 20 mA
$943.00
In Stock
In Stock
Compliance HT-2000P V2 - Hipot Tester, 0-2000 VAC @ 20 mA Specs
| Voltage Test Type | AC |
| Maximum Output Voltage | 2000 VAC |
| Maximum Leakage Current | 20 mA AC |
| Leakage Current Adjustment | 1-20 mA AC, increments of 0.1 mA |
| Input Voltage | 120 VAC |
| Frequency | 60 Hz |
| Fuse | 120/230 VAC 2 A Slow Blow |
| Breakdown Detect | Independent High Frequency Circuit (50 KHz - 500 KHz) |
| Transformer Power | < 500 VA |
| Leakage Current Detect | Independent Low Frequency Circuit |
| Ramp Time Range | 1 - 5 seconds |
| Test Time Range | 1 - 60 seconds |
| Discharge Time | <7ms for AC <1.3s for Max DC at Open Circuit |
| Display | 4 Digits LED Display |
| Voltage Meter Accuracy | ± 2 % |
| Leakage Accuracy | ± 0.1 mA |
| Ground Continuity | 2.93Ω Defeatable |
| Duty Cycle | 100 % |
| Pass/Fail Repeatability | ± 3% |
| Operation Temperature | 15 - 40 °C |
| Relative Humidity Range | 0 - 90 % Non-Condensing |
| Output Connector | NEMA 5-15R Receptacle and 4mm H.V. Socket output |
| Dimensions | 9-1/4" Wide x 4-3/4" High x 10" Deep |
| Weight | ~11 lbs |
| Product Package | HT-S Hipot Tester HT-S Product Manual 18 AWG Line Power Cord Ground Return Lead, 18AWG, 4ft long (1 x PN:00-GL) Ground Continuity Connector Tip (1 x PN: 00-GPIN) NIST Traceable Calibration Certificate to MIL-STD45662-A Calibration Data Copy |
| 00-HVTL-R-6 | High Voltage Test Lead, 5Kv, Red 6ft long |
| 00-TL | TestLink option. Allows connection with GF-30AC-T for Ground Bond Test |
| 00-TLC | TestLink Cableset. (For 00-TL) |
| 00-RI | Relay Interface/PLC Interface. Test signals through relay contacts/coils |
| 00-AR | Auto Reset on Pass option. Resets after passing test |
| 00-HTT-1 | Function Checker: Allows verification of functionality/calibration of your tester |
| Output Voltage Indicator | Provided by front panel meter, directly connected to high voltage output |
| Failure Indicator | Visual, Provided by red LED's Test automatically terminated on failure |
| Leakage Test | Factory setting set for pass/fail point (also user adjustable) 5 mA AC and 2 mA DC |
| Operation Instructions | Provided on rear panel |
- HT-S Hipot Tester
- HT-S Product Manual
- 18 AWG Line Power Cord
- Ground Return Lead, 18AWG, 4ft long (1 x PN:00-GL)
- Ground Continuity Connector Tip (1 x PN: 00-GPIN)
- NIST Traceable Calibration Certificate to MIL-STD45662-A
- Calibration Data Copy