Vitrek 952i – 6KV AC/DC/IR/GB/LR Electrical Safety Compliance Analyzer
$4,580.00
In Stock
In Stock
Vitrek 952i - 6KV AC/DC/IR/GB/LR Electrical Safety Compliance Analyzer Specs
| DC Output Voltage | 30V to 6500V (951i & 952i) 50V to 11000V (953i,954i & 955i) |
| Resolution | 0.1V up to 999.9V, 1V above |
| Accuracy | 0.25% + 0.5V ( 1 year 23°C ± 3°) |
| DC Current Sourcing | 50mA max, 25mA above 6000V (951i & 952i) 30mA max, 20mA above 6000V, 10mA above 7500V, 5mA above 9000V (953i, 954i, 955i) |
| Ramp Time | 0.01 to 9999sec, 0.01sec resolution or 0.1 to 50000V/sec, 0.1V/sec resolution |
| Dwell Time | 0.02 to 9999 seconds or user terminated, 0.01sec resolution |
| Discharge | 25mA max in solid-state constant current discharge mode, selectable same as ramp rate or ramp to next level if next step is DCW, DCez or DCIR |
| DC Leakage Current | Measurement Range: 0 to +/-200mA, |
| Resolution | 4 digits (9999 counts) down to 100pico-amp |
| Accuracy | 0.25% + 0.5nA + ½ digit ( 1 year 23°C ± 3°) |
| Min & Max Current limits | Selectable for Ramp and Dwell 100 pico-amps and up |
| Measurement Period | 1 power line cycle (50/60Hz) |
| Insulation Resistance (IR) | Test modes include: End on pass reading, end on fail or end on dwell timer |
| Test Voltage | 5% Accuracy* Max resistance |
| 500V | 50GΩ |
| 1000V | 100GΩ |
| 2500V | 250GΩ |
| 5000V | 500GΩ |
| 10000V | 1TΩ |
| AC Output Voltage | 20V to 6000V RMS (951i, 952i, 953i, 954i) 50V to 10,000V RMS (955i) 100V to 30,000V RMS (option AC-30) |
| Resolution | 0.1V up to 999.9V, 1V above |
| Accuracy | 0.5% + 1.5V (+ 0.01% per Hz above 100Hz) |
| AC Current Sourcing | 50mA RMS max (951i, 952i, 953i, 954i) 30mA RMS max , (955i) 200mA RMS with option AC-2 (2KVAC RMS max output) 10mA RMS Max with AC-30 option |
| Output Frequency | Digitally synthesized, low distortion sinewave 20Hz to 500Hz, standard or AC-2) 40Hz to 500Hz, (955i) 0.1% accuracy, 0.1Hz resolution (1Hz above 99.9Hz) |
| Ramp Time | 0 to 9999sec, 0.01sec resolution or 0.1 to 100000V/sec, 0.1V/sec resolution |
| Dwell Time | 0.02 to 9999 seconds or user terminated, 0.01sec resolution |
| Accuracy | 0.05% + 20mS |
| Ramp Down | Selectable same as ramp time or ramp to next level if next test step is an ACV test type |
| AC Leakage Current | Measurement Range: 0 to +/-200mA RMS |
| Resolution | 4 digits (9999 counts) down to 100pico-amps |
| Accuracy | 0.5% + 10nA (add 0.005% per Hz above 100Hz) Selectable min & max limits for Ramp & Dwell, from 100 pico amps up Measurement Period: 1 power line cycle (50/60Hz) |
| Phase Measurement | Total RMS current, In-phase current, Quadrature current (reactive/out-of-phase) |
| Accuracy | 0.01° per Hz, relative to output voltage |
| AC Insulation Resistance | Test modes include: End on pass reading, end on fail or end on dwell timer |
| Test Voltage (50/60Hz) | 10% Accuracy* Max resistance |
| 500V | 5GΩ |
| 1000V | 10GΩ |
| 2500V | 25GΩ |
| 5000V | 50GΩ |
| 10000V (955i only) | 100GΩ |
| Test Current | 0.1 to 40A RMS, 0.001A resolution |
| Accuracy | 0.5% + 5mA accuracy (add 0.005% per Hz above 100Hz) |
| Test Frequency | 40Hz to 500Hz |
| Resolution | 0.1Hz (1Hz above 99.9Hz) Accuracy: 0.1% accuracy |
| Waveform | Digitally synthesized, low distortion sinewave |
| Measurement Configuration | 4-Terminal Kelvin |
| Compliance Voltage | 6.5V RMS, may be user limited to a lower level with 0.01V resolution |
| Resistance Range | 6.5 ohms at 1A decreasing to 162.5 milli-ohms max at 40A |
| Max load impedance | 10 ohms |
| Ramp Time | 0 to 9999sec, 0.01sec resolution |
| Accuracy | (1% + 0.1sec) accuracy |
| Dwell Time | 0.02 to 9999sec or user terminated, 0.01sec resolution |
| Accuracy | 0.05% + 20ms |
| Ramp Down | Fast (35mS), same rate as ramp up or may be skipped if next test step is a ground bond test |
| Voltage Sense | Range: 0 to 8 v rms |
| Resolution | 4 digits down to 10uV Accuracy: 0.5% + 30uV |
| Phase Measurement | RMS, In-phase and Quadrature measurements 0.01° per Hz phase relative to test current |
| Measurement Range | 0 to 150Kohm (999.9mΩ to 99.99KΩ, 149.9KΩ in 7 ranges) |
| Resolution | 4 digits, 100µΩ on 1ohm range |
| Test Current | 55mAdc constant current up to ≈ 91Ω, 5VDC constant V above |
| Accuracy (4-wire) | 0.5% + 0.002ohm + ½ digit up to 30K ohm 1.5% + ½ digit above 30K ohm 5% + 1 digit from 100K to 150K ohm Add 20mΩ for 2 -wire |
| Voltage Measurement | 0 to ± 8KVDC 6KV RMS AC (951i & 952i) 0 to ± 11KVDC 8KV RMS AC (953i & 954i) 0 to ± 11KVDC 10KV RMS AC ( 955i) |
| Resolution | 0.1V, 1 V above 999.9V |
| DC Accuracy | 0.25% + 0.5V |
| AC Accuracy | 0.5% + 1.5V |
| Leakage Current | 0 to ± 200mA DC or RMS AC |
| Resolution | 4 digits (9999 counts) down to100pico-amps |
| DC Accuracy | 0.25% + 0.5nA |
| AC Accuracy | 0.5% + 20nA |
| Test Results Test Time | 0.02 to 9999 sec Last, Minimum, Average & Max V& A reading plus arc current |
| Test Waveform | Trapezoidal (Selectable positive polarity, negative polarity or bi-polar) |
| Ramp Up/Down Time | 1ms (0.5ms for option AC2) to 30mS with 0.1ms resolution |
| Dwell Time | 1ms (0.5ms for option AC2) to 30mS with 0.1ms resolution |
| Test Voltage | 50V to 8000V (20V to 2750V with option AC-2) |
| Resolution | 0.1V up to 999.9V, 1V above |
| Accuracy | 0.25% + 1.5V |
| Test Lead Safety Sense | TLSS™ Technology continuously verifies that test leads are properly connected prior to and during HV, 4-wire Low Ohms and Ground Bond testing |
| Arc Detection Sensitivity | User selectable 3 microseconds to 30 microseconds. |
| Dwell Time Accuracy | Accuracy: 0.05% + 20mS |
| RS232 Interface | Digital I/O, VICL: Vitrek auxiliary unit control loop Remote Interface Option "IF-3": GPIB - IEEE-488.2 Subset compatible RS232C - 1200, 2400, 4800, 9600 Baud rate selectable Parallel - IBM/Centronics compatible |
| Accuracy | Stated specifications are bipolar and apply for one year within 5°C from calibration temperature (20 to 25°C). |
| Operating Temperature | 0 C to 50° C |
| Humidity | 90% RH, 0 to 40° C |
| Power | 115/230 VAC + 10%, 350 VA Max |
| Dimensions | 89mm H x 432mm W x 457mm D (3.5" H x 17" W x 18" D) |
| Weight | 9Kg (18 lb.) Net / 18Kg (25 lb.) shipping (951i, 953i, 959i) 14Kg (28 lb.) Net / 18Kg (35 lb.) shipping (952, 954i, 955i) |
- 6KV AC/DC/IR/GB/LR Electrical Safety Compliance Analyzer
- TL-209
- K-2R
- Power Cord
- Operating Manual
- QTPro II-950 45 day free trial
- NIST Traceable Calibration Certificate without data








Reviews