PIE 850 10-50 mA Multifunction Process Calibrator
$3,518.00
In Stock
In Stock
PIE 850 10-50 mA Multifunction Process Calibrator Specs
| Operating Temperature Range | -20 to 60 °C (-5 to 140 °F) |
| Storage Temperature Range | -30 to 60 °C (-22 to 140 °F) |
| Temperature effect | = ± 0.005 %/°C of Full Scale |
| Relative Humidity Range | 10 % =RH =90 % (0 to 35 °C), Non-condensing 10 % =RH= 70 % (35 to 60 °C), Non-condensing |
| Common Mode Rejection | 50/60 Hz, 100 dB |
| Normal Mode Rejection | 50/60 Hz, 50 dB |
| Noise | = ± ½ Least Significant Digit from 0.1 to 10 Hz |
| Size | 5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (L x W x H) |
| Weight | 12.1 ounces, 0.34 kg (including boot & batteries) |
| Batteries | Four “AA” Lithium 1.5V (LR6) |
| Battery Life | Read Functions = 20 hours; Read Pressure = 7 hours Source mA: = 14 hours @ 12 mA into 250O = 9.5 hours @ 30 mA into 250O Pwr/Meas: = 12 hours @ 20 mA, = 4.5 hours @ 50 mA Source V, O, T/C, pH, RTD & Hz = 20 hours |
| Low Battery | Low battery indication with nominal 1 hour of operation left |
| Protection against misconnection | Over-voltage protection to 60 vrms (rated for 30seconds). Red LED indicates OVERLOAD or out of range conditions |
| Display | High contrast graphic liquid crystal display with 0.35” (9 mm) high digits on main & 0.2” (5 mm) on mA display. LED backlighting for use in low lit areas. |
| Ranges and Resolution | 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA 0.000 to 52.000 mA or -25.00 to 105.00% of 10-50 mA |
| Accuracy | = ± (0.02 % of Reading + 0.003 mA) |
| Voltage burden | = 2V at 24 mA. = 2 V at 52 mA. |
| Overload/Current limit protection | 25 mA nominal in 20 mA range 52.5 mA nominal in 50 mA range |
| Ranges and Resolution | 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA 0.000 to 52.000 mA or -25.00 to 105.00% of 10-50 mA |
| Accuracy | = ± (0.02 % of Reading + 0.003 mA) |
| Loop compliance voltage | = 24 DCV @ 20.00mA. = 2 DCV @ 50.000mA |
| Loop drive capability | 1200 O at 20 mA for 15 hours nominal; 800 O at 50 mA for 4.5 hours nominal Subtract 250O with Hart Resistor enabled (4-20 Only) |
| Accuracy | Same as Source/Power & Measure |
| Voltage burden | = 2V at 24 mA. = 2 V at 52 mA. |
| Overload/Current limit protection | 25 mA nominal in 20 mA range 52.5 mA nominal in 50 mA range |
| Loop voltage limits | 2 to 60 VDC (fuse-less protected from reverse polarity connections) |
| Accuracy in mV Accuracy in pH | = ± (0.02 % of Reading in mV + 0.1 mV) = ± 0.003 pH @ 25°C |
| Range and Resolution | ±99.999 mV, ±999.99mV, 0 to 10.250 V, 0.00 to 60.00 V DC |
| Accuracy | = ± (0.02 % of Reading + 0.01% Full Scale) |
| Input resistance | = 1 MO |
| Ranges and Resolution | -20.000 to 99.999 mV, -500.00 to 999.99 mV, 0.000 to 10.250V |
| Accuracy | = ± (0.02 % of Reading + 0.01% Full Scale) |
| Source Current | = 20 mA |
| Sink Current | > 16 mA |
| Output Impedance | < 1 Ohm |
| Short Circuit Duration | Infinite |
| Accuracy | = ± (0.02 % of Reading + 0.01 mV) |
| Cold Junction Compensation | ± (0.1°C + 0.005%/°C) |
| Output Impedance | < 1 Ohm |
| Source Current | > 20 mA (drives 80 mV into 10 Ohms) |
| Accuracy & Cold Junction Compensation | Same as Thermocouple Source |
| Input Impedance | > 1 Megohms |
| Open TC Threshold; Pulse | 10K Ohms; <5 µamp pulse for 300 milliseconds (nominal) |
| Resistance Ranges | 0.00 to 401.00, 0.0 to 4010.0 Ohms |
| Accuracy | ±(0.025% of Reading + 0.075 Ohms) |
| Excitation Current | 1.0 mA to 401 Ohms, 0.5 mA to 4010 Ohms (nominal) |
| Continuity | 0.0 to 401.0 Ohms; Beeps from 0.0 to 100.0 Ohms |
| 3 Wire & 4 Wire Accuracy From 1 to 10.2 mA External Excitation Current Below 1 mA of External Excitation Current 2 Wire Accuracy | ±(0.025% of Reading + 0.075 Ohms) ±(0.025% of Reading+0.075 Ohms + ) Add 0.1 Ohms to 3 Wire & 4 Wire Accuracy |
| Resistance Ranges | 0.00 to 401.00 to 4010.0 Ohms |
| Allowable Excitation Current Range | <401 Ohms: 10.2 mA max; steady or pulsed/intermittent 401 to 4010 Ohms: 1 mA max; steady or pulsed/intermittent |
| Pulsed Excitation Current Compatibility | DC to 0.01 second pulse width |
| Ranges | 1 to 2000 CPM, 0.01 to 999.99 Hz, 0.1 to 9999.9 Hz, 0.001 to 20.000 kHz |
| Accuracy | ±(0.02% of Reading + 0.01% of Full Scale) |
| Output Waveform | Square Wave, Zero Crossing -1.0 to +5 V peak-to-peak ±10% |
| Risetime (10 to 90% of amplitude) | < 10 microseconds |
| Output Impedance | < 1 Ohm |
| Source Current | > 1 mA rms at 20 kHz |
| Short Circuit Duration | Infinite |
| Optical Coupling | Green LED (HZ SYNC) flashes at output frequency |
| Ranges & Accuracy | Same as Frequency Source |
| Accuracy | ±(0.02% of Reading + 0.01% of Full Scale) |
| Trigger Level | 1 V rms, dc coupled |
| Input Impedance | > 1 Meg Ohm + 60 pF |
- (4) "AA" Lithium Ion Batteries
- Certificate of Calibration with Test Data
- Blue Rubber Boot
- Evolution Hands Free Carrying Case
- Evolution mA/V Test Leads
- Evolution RTD Wire Kit